Selection Instructions
F286_DLIMT
The function compares the input value at input s3_In with a lower and an upper limit. The lower
Description
limit is specified at input s1_Min, and the upper limit at input s2_Max. The result of the function is
returned at output d as follows:
If the input value at s3_In < s1_Min, the lower limit at input s1_Min is returned at
output d.
If the input value at s3_In > s2_Max, the upper limit at input s2_Max is returned
at output d.
If the input value at s2_Max  s3_In  s1_Min, the input value s3_In is returned
unchanged at output d.
If you want to control the output value solely via the upper value s2_Max, set -2147483648 or
16#80000000 for the lower limit s1_Min. To perform lower limit control only, set 2147483647 or
16#7FFFFFFF the upper limit s2_Max.
Lower limit s1
This instruction also exists as a P instruction (for FP2/2SH, FP3/5, FP10/10SH PLC types), which
is only executed at the rising edge of the EN trigger. Select [Insert P instruction] from the
"Instructions" pane if you require a P instruction. To facilitate reuse, the instruction then appears
under "Recently used" in the pop-up menu. Press <Ctrl>+<Shift>+<v> within the programming
area to open the list of recently used elements.
PLC types
Availability of F286_DLIMT (see page 1323)
Data types
Variable
Data type
s1_Min
s2_Max
ANY32
s3_In
d
880
32-bit data upper and lower limit control
Output value d
[s2]
Input value s3
Upper limit s2
[s1]
Function
the area where the lower limit is stored or the lower limit data
the area where the upper limit is stored or the upper limit
data
the area where the input value is stored or the input value
data
the area where the output value data is stored