High-speed counter instructions
HscInfo_GetControl
Code
This instruction returns the control code (see page 891) of the high-speed counter channel
Description
specified by iChannel.
See also:
Tool instructions: overview of high-speed counter instructions
see page 1327
PLC types
Data types
Variable
iChannel
Output variable
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
Example
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if
(bGetControlCode)
wChannelControlCode
end_if;
1156
Returns control code of high-speed counter channel
Data type
Function
INT
High-speed counter channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
WORD
Stores the control code
then
:=
HscInfo_GetControlCode(iChannel
:= iChannel);

Advertisement