F152_RMRD
Reads data from the specified intelligent unit of the MEWNET-F Slave station.
Description
s1 stores the control data for the configuration of the Master and Slave units in the network. n
words are read beginning from the shared memory address number in the intelligent unit specified
by s2. The result is stored in d.
This instruction also exists as a P instruction (for FP2/2SH, FP3/5, FP10/10SH PLC types), which
is only executed at the rising edge of the EN trigger. Select [Insert P instruction] from the
"Instructions" pane if you require a P instruction. To facilitate reuse, the instruction then appears
under "Recently used" in the pop-up menu. Press <Ctrl>+<Shift>+<v> within the programming
area to open the list of recently used elements.
Specifications of s1:
s1 higher word
Bit
s1 high word
s1 lower word
Bit
s1 low word
Reference:
Availability of F152_RMRD (see page 1321)
PLC types
Data types
Variable
Data type
DWORD
s1
ANY16
s2
INT
n
ANY16
d
The variables s2 and d have to be of the same data type.
792
Data read from the slave station
· · ·
· ·
·
·
15
12 11
8 7
Bank No.
(16#00 to 16#FF if
(16#00 to 16#1F,
there is a bank to
FP3: to 16#17)
specify, otherwise
16#00)
· · ·
· ·
·
·
15
12 11
8 7
Master station No.
Slave station No.
(16#01 to 16#04)
(16#01 to 16#20)
Intelligent unit with bank
Name
FP3 expansion data memory
unit
Function
stores control data for Master/Slave configuration
starting memory address number of words to be read
number of words to be read (max. 32 words)
starting 16-bit area where words read are stored, (see F153
(see page 794))
· ·
4 3
0
Slot No.
· ·
4 3
0
Order Number
AFP32091
AFP32092