Appendix Programming Information
Type
External input relays
Pulse relays
Special internal relays
Memory area [words]
Type
External input relays
External output relays
Internal relays
Link relays
Data registers
1)
Link registers
1)
Timer/counter set value
area
1)
Timer/counter elapsed
value area
1)
File
12k type
registers
1)
32k type
3)
(expanded)
Special data registers
Index registers
Memory area [double words]
Type
External input relays
1)
External output relays
1)
1266
Memory
Available address area
size
F/P
2048
X0–X127F
1024
P0–P63F
176
R9000–R910F
Memory
Available address area
size
F/P
128
WX0–WX127
128
WY0–WY127
253
WR0–WR252
128
WL0–WL127
6000
DT0–DT5999
256
LD0–LD255
1024
SV0–SV1023
1024
EV0–EV1023
14333
FL0–FL14332
30717
FL0–FL30716
256
DT90000–
DT90255
14
I0–ID
Memory
Available address area
size
F/P
64
DWX0–DWX72
64
DWY0–DWY72
IEC
%IX0.0–
Turn on or off based on external
%IX127.15
input.
%MX11.0.0–
Turn on for one scan only. Used
%MX11.63.15
internally by the PLC program.
%MX0.900.0–
Turn on or off based on specific
%MX0.910.15
conditions. Used internally as a
flag.
IEC
%IW0–
Code for specifying 16 external
%IW127
input points as one word (16 bits)
of data.
%QW0–
Code for specifying 16 external
%QW127
output points as one word (16
bits) of data.
%MW0.0–
Code for specifying 16 internal
%MW0.252
relays as one word (16 bits) of
data.
%MW7.0–
Code for specifying 16 link relays
%MW7.127
as one word (16 bits) of data.
%MW5.0–
Data memory used in a program.
%MW5.5999
Data is handled in 16-bit units
(one word).
%MW8.0–
Data memory shared by multiple
%MW8.255
PLCs connected using PLC link.
Data is handled in 16-bit units
(one word)..
%MW3.0–
Data memory for storing the set
%MW3.1023
values of timers or counters. The
values are stored by
timer/counter number.
%MW4.0–
Data memory for storing the
%MW4.1023
elapsed values during operation
of timers or counters. The values
are stored by timer/counter
number.
%MW9.0–
Data memory used in a program.
%MW9.14332
Data is handled in 16-bit units
(one word).
%MW9.0–
%MW9.30716
%MW5.90000–
Data memory for storing settings
%MW5.90255
and error codes.
%MW6.0–
Data memory used to modify
%MW6.13
constants and memory area
addresses.
IEC
%ID0–
Code for specifying 32 external
%ID72
input points as a double word (32
bits) of data.
%QD0–
Code for specifying 32 external
%QD72
output points as a double word
(32 bits) of data.
Function
Function
Function