Panasonic FP Series Programming Manual page 1166

Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

HscInfo_ReadTarget
Value
This instruction reads the target value from the high-speed counter channel specified by iChannel.
Description
See also:
Tool instructions: overview of high-speed counter instructions
Data types
Variable
iChannel
Output variable
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
Example
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if
(bReadTargetValue)
diTargetValue
end_if;
Reads target value from high-speed counter channel
Data type
Function
INT
High-speed counter channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
DINT
Stores the target value of the channel specified by iChannel
then
:=
HscInfo_ReadTargetValue(iChannel
High-speed counter instructions
:= iChannel);
1165