High-speed counter instructions
HscControl_HscInstruction
Clear
This instruction cancels the execution of a high-speed counter instruction on the channel specified
Description
by iChannel. Bit 3 of the high-speed counter control code (see page 891) is set to TRUE and
subsequently reset to FALSE.
See also:
Tool instructions: overview of high-speed counter instructions
To add an enable input and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
see page 1327
PLC types
Data types
Variable
iChannel
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
Example
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
When the variable bClearHscInstruction is set to TRUE, the execution of a high-speed counter
instruction on the channel specified by iChannel is canceled.
LD
ST
1148
Clears high-speed counter instruction
Data type
Function
INT
High-speed counter channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1