Appendix Programming Information
40.7.7 Relays and memory areas for FP2SH
Relays [bits]
Type
External input relays
External output relays
Internal relays
1)
Link relays
1)
Timer relays
1) 2)
Counter relays
1) 2)
Pulse relays
Error alarm relays
Special internal relays
Memory area [words]
Type
External input relays
External output relays
Internal relays
Link relays
Data registers
1)
Link registers
1)
Timer/counter set value
area
1)
1268
Memory
Available address area
size
F/P
8192
X0–X511F
8192
Y0–Y511F
14192
R0–R886F
10240
L0–L639F
3072
T0–T2999/
C3000–C3071
3072
C3000–C3071/
T0–T2999
2048
P0–P127F
2048
E0–E127F
176
R9000–R910F
Memory
Available address area
size
F/P
512
WX0–WX127
512
WY0–WY127
887
WR0–WR252
640
WL0–WL127
10240
DT0–DT5999
8448
LD0–LD255
3072
SV0–SV1023
IEC
%IX0.0–
Turn on or off based on external
%IX511.15
input.
%QX0.0–
Turn on or off external outputs
%QX511.15
based on the operation result.
%MX0.0.0–
Used internally by the PLC
%MX0.886.15
program to store bit information.
%MX7.0.0–
Shared by multiple PLCs
%MX7.639.15
connected using PLC link.
%MX1.0–
Turn on when the value set with
%MX1.2999/
a TM instruction for the timer with
%MX2.3000–
the same number has reached 0.
%MX2.3071
%MX2.3000–
Turn on when the value set with
%MX2.3071/
a CT instruction for the counter
%MX1.0–
with the same number has
%MX1.2999
reached 0.
%MX11.0.0–
Turn on for one scan only. Used
%MX11.127.15
internally by the PLC program.
%MX10.0.0–
Turns on in the event of error.
%MX10.127.15
The error history is stored in
dedicated data registers.
%MX0.900.0–
Turn on or off based on specific
%MX0.910.15
conditions. Used internally as a
flag.
IEC
%IW0–
Code for specifying 16 external
%IW127
input points as one word (16 bits)
of data.
%QW0–
Code for specifying 16 external
%QW127
output points as one word (16
bits) of data.
%MW0.0–
Code for specifying 16 internal
%MW0.252
relays as one word (16 bits) of
data.
%MW7.0–
Code for specifying 16 link relays
%MW7.127
as one word (16 bits) of data.
%MW5.0–
Data memory used in a program.
%MW5.5999
Data is handled in 16-bit units
(one word).
%MW8.0–
Data memory shared by multiple
%MW8.255
PLCs connected using PLC link.
Data is handled in 16-bit units
(one word)..
%MW3.0–
Data memory for storing the set
%MW3.1023
values of timers or counters. The
values are stored by
timer/counter number.
Function
Function