Transistor types (C16 and higher)
CPU outputs which have been specified as pulse output or PWM output
cannot be used as normal outputs.
Input numbers X4 to X7 can be used as home input of pulse output
channels 0 to 3. When using the home return function, always set the home
input. In this case, X4 to X7 cannot be used as high-speed counter inputs.
The output numbers for the deviation counter clear signal, which can be
used with the home return function, are fixed for each channel.
For C16: Channel 0 = Y6, channel 1 = Y7
For C32/T32/F32: Channel 0 = Y8, channel 1 = Y9, channel 2 = YA, channel 3
= YB
If used for the deviation counter clear signal, these outputs are not available
as pulse outputs.
Time Constants
No.
Name
Time constant of input X0
430
Time constant of input X1
430
Time constant of input X2
430
Time constant of input X3
430
Time constant of input X4
431
Time constant of input X5
431
Time constant of input X6
431
Time constant of input X7
431
Time constant of input X8
432
1)
Time constant of input X9
432
1)
Time constant of input XA
432
1)
Time constant of input XB
432
1)
Time constant of input XC
433
1)
Time constant of input XD
433
1)
Time constant of input XE
433
1)
Time constant of input XF
433
1)
32k types only
1)
TOOL Port
No.
Name
TOOL port - communication mode
412
TOOL port -station number
410
TOOL port - baud rate
415
TOOL port - sending data length
413
1292
Default
Values
1.0ms
0.1ms
0.5ms
1.0ms
2.0ms
4.0ms
8.0ms
16.0ms
32.0ms
64.0ms
Default
Values
MEWTOCOL-COM
MEWTOCOL-COM
Slave
Slave/Program
controlled
1
1–99
115200 baud
115200/57600/38400/
19200/9600/4800/240
0 baud
8 bits
7 bits/8 bits