Name
No.
Number of
409
temperature input
values for averaging
process
If the same input has been set as high-speed counter input, pulse catch
input or interrupt input, the following order of precedence is effective:
High-speed counter  Pulse catch  Interrupt.
If reset input settings overlap for channel 0 and channel 1, the channel 1
setting takes precedence. If reset input settings overlap for channel 2 and
channel 3, the channel 3 setting takes precedence.
The input modes two-phase, incremental/decremental, or
incremental/decremental control require a second channel. If channel 0 or
channel 2 have been set to one of these modes, the settings for channel 1
and channel 3, respectively, will be invalid.
The settings for pulse catch inputs and interrupt inputs can only be
specified in the system registers.
TOOL Port
No
Name
.
410 TOOL port - station number
411 TOOL port - modem connection
411 TOOL port - sending data
length
414 TOOL port - baud rate
COM Port
No.
Name
COM port 1 - communication mode
412
COM port 1 -station number
415
COM port 1 - baud rate
414
COM port 1 - sending data length
413
COM port 1 -sending parity check
413
COM port 1 - sending stop bit
413
COM port 1 - sending start code
413
COM port 1 - sending end code/reception done condition
413
COM port 1- -receive buffer starting address
417
COM port 1 - receive buffer capacity
418
COM port 1 - modem connection
416
Default
Values
0
0–50
Default
Values
1
1–32
Disable
Disable/Enable
8 bits
7 bits/8 bits
19200 baud
19200/9600 baud
Appendix Programming Information
Default
Values
MEWTOCOL-CO
MEWTOCOL-COM
M Slave
Slave/Program
controlled/Modbus RTU
Slave
1
1–99
9600 baud
19200/9600/4800/2400/12
00/600/300 baud
8 bits
7 bits/8 bits
With-Odd
None/With-Odd/With-Even
1 bit
1 bit/2 bits
No-STX
No-STX/STX
CR
CR/CR+LF/ETX/None
0
0–1657
0
0-1658
Disable
Disable/Enable
1299