Panasonic FP Series Programming Manual page 1028

Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

F166_PulseOutput_
Set
If the elapsed value matches the target value of the selected pulse output channel, the specified
Description
output immediately turns to TRUE.
Pulse output characteristics
10000
0
2
3
4
10000
Target value
Elapsed value of pulse output
1
Execution condition
2
"Output control active" flag
3
PLC output
4
The PLC output turns to TRUE when the elapsed value matches the target value. In addition, the
"Output control active" flag turns to FALSE and the instruction is deactivated.
If an output is specified that has not been implemented, only the internal memory of the
corresponding WY address is set or reset.
Interrupt operation
The interrupt program will be executed when the elapsed value matches the target value. Any
interrupt that has been entered into the Tasks list is automatically enabled. A special interrupt
program number is assigned to each channel number.
Channels used by interrupt programs:
Interrupt 8
Interrupt 9
Interrupt 10
Interrupt 11
 General programming information
Set "Pulse output" for the desired channel in the system registers.
Target value match ON (pulse output)
1
Channel 0
Channel 1
Channel 2
Channel 3
Pulse output instructions