Panasonic FP Series Programming Manual page 976

Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

F181_DSP
The FP-e display mode is changed to the one specified using s1.
Description
Availability of F181_DSP (see page 1322)
PLC types
Data types
Variable
Data type
ANY16
s1
Operands
For
WX
s1
Specifying "s1" registration display
Values for "s1"
0
1
2
3
4
5
6
7
(N=normal mode, S=switch mode, R=register mode, I=I/O monitor mode).
Error flags
No.
IEC address
R9007
%MX0.900.7
R9008
%MX0.900.8
In this example the function has been programmed in ladder diagram (LD) and structured text
Example
(ST).The same POU header is used for all programming languages.
Screen change instruction
Function
Display mode and No. (0 to 7 can be specified).
Relay
T/C
WY
WR
-
SV
Display type
N mode 1st screen
N mode 2nd screen
S mode 1 st screen
S mode 2nd screen
R mode 1st screen
R mode 2nd screen
I mode 1st screen
I mode 2nd screen
Set
If
permanently
for an instant
 If a value other than "0" to "7" is specified for "s1", an operation
error will occur.
 This instruction cannot be used during an interrupt program.
Register
EV
DT
IX
IY
 the area specified using the Index modifier
exceeds the limit.
 the value "s1" is not "0" to "7".
FP-e display instructions
Constant
dec. or hex.
975

Advertisement

Table of Contents
loading

Table of Contents