4. Commissioning
4.3

Checking the valves and the valve/actuator combination

4−8
Note
Before commissioning the VTSA... valve terminal, note
the specifications concerning the medium; see Chapter 3
Installation," section Pilot control (pilot air supply)."
The VTSA... valve terminal can be commissioned as follows:
Commissioning variants
Preliminary test of the pneuma
tic tubing
Complete commissioning of the
overall system
Tab. 4/3: Commissioning variants
Commissioning the pneumatic components by means of the
manual override is described below.
Commissioning of the CPX terminal is described in the corre
sponding manual for the CPX fieldbus node.
Activity
Test the valve/actuator combina
tion by means of the manual
override
Installing and connecting the
overall system.
Program control via PLC/indu
strial PC.
Festo P.BE−VTSA−44−EN en 0905e