5. Maintenance and conversion

5.3.2 Replacing/adding components for vertical stacking

Festo P.BE−VTSA−44−EN en 0905e
The valve terminal can be fitted with the following compo
nents for vertical stacking:
Pressure regulator plate
Flow control plate
Vertical pressure shut−off plate
Vertical pressure supply plate
Note
No valve function.
Do not combine standard 2x3/2−way valves (identifier
T32C−A, T32H−A, T32U−A) with reversible pressure regula
tor plates (identifier R5−..., R6−..., R7−...). With this combina
tion, the pneumatic spring of the valves does not function.
The valves cannot return from the switching position to the
neutral position.
Vertical stacking with pressure regulator plate:
In the combination pressure regulator plate with flow control
plate, vertical pressure shut−off plate or vertical pressure
supply plate, you must fit the above−mentioned components
under the pressure regulator plate. You thereby guarantee
free access to the adjusting screws and connections (see
Tab. 5/4).