Festo VTSA Series Description page 71

Valve terminal with vtsa pneumatics
Hide thumbs Also See for VTSA Series:
Table of Contents

Advertisement

2. Mounting
Assembly
Festo P.BE−VTSA−44−EN en 0905e
Caution
The VTSA... valve terminals can bend and therefore be
damaged if they are mounted on an uneven pliable sur
face.
Mount the valve terminal only on a flat rigid surface.
·
Overloading the mounting holes, bending the VTSA... valve
terminal with CPX terminal or internal vibrations can cause
damage.
Use additional mounting brackets of the following type
·
for valve terminals with more than five manifold sub−
bases: VAME−S...−10−W. The pneumatic supply plates
have appropriate threaded holes for mounting the
brackets (tightening torque 3.0 Nm).
In these cases, use the additional mountings for the CPX
·
terminal (see instructions in the description of the CPX
system).
Proceed as follows:
1. Make sure that the mounting surface is flat and that it
can support the VTSA... valve terminal (for weights,
see Appendix A, Tab. A/2).
Make sure there is sufficient space for connecting the power
supply cables and tubing.
2. Drill mounting holes in the mounting surface.
3. Fasten the valve terminal to the mounting surface with M5
or M6 screws of sufficient length.
2−11