5. Maintenance and conversion
Mounting
1
Manifold
sub−base
2
Guide pins
3
Seal plate
(optionally with
duct separation)
Fig. 5/4: Mounting manifold sub−bases
5−16
Proceed as follows:
1. Make sure the seals are not damaged. Replace the seals if
they are damaged.
2. Place the seal plate onto the guide pins of the manifold
sub−base or of the pneumatic supply plate (for seal plates
with duct separation, see Chapter 3.3.3).
1
2
3
2
1
Festo P.BE−VTSA−44−EN en 0905e