1. Overview of components
Manifold sub−bases
Type:
4)
VABV...−2T1
4)
VABV...−T1
5)
VABV...−2T2
5)
VABV...−T2
1) The max. number of valve positions only applies if the VTSA is fitted only with the manifold
sub−base type shown
2) Max. 4 solenoid coils can be actuated
3) Max. 8 solenoid coils can be actuated
4) These manifold sub−bases support actuation of only one solenoid coil per valve position
5) These manifold sub−bases support actuation of two solenoid coils per valve position
Tab. 1/5: Number of valve positions for VTSA... with AS−interface
1−8
Width
18 mm or 26 mm
42 mm or 52 mm
18 mm or 26 mm
42 mm or 52 mm
Number of valve positions for VTSA...
1)
with AS−interface
2)
VTSA−4E4A−Z
2 or 4
1, 2, 3 ... 4
2
1 or 2
Festo P.BE−VTSA−44−EN en 0905e
3)
VTSA−8E8A−Z
2, 4, 6 ... 8
1, 2, 3 ... 8
2 or 4
1, 2, 3 ... 4