ATTENTION:
NOTE: The reset modes listed close all open IP and Telnet connections and all sockets.
Mode
Activation
1
Using an Extron Tweeker or other small
screwdriver, press and hold in the
Reset
recessed
button for 30 seconds
while applying power to the switcher.
NOTE:
After a mode 1 reset,
update the device with the latest
firmware version. DO NOT
operate with the firmware version
that results from this mode reset.
This temporarily resets the device
to factory default until power is
recycled. To use factory default
firmware, re-upload that version.
4
Press and hold down the
until the Reset LED blinks two times
(at 9 seconds). Then, press
momentarily (less than 1 second).
5
Press and hold down the
until the Power LED blinks three times
(approximately 9 seconds). Then,
Reset
press
momentarily (less than
1 second).
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or unit reboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du processeur.
Each mode is a separate function, not a continuation from mode 1 to mode 5.
Reset Mode Summary
The device reverts to the factory default
firmware.
Firmware reverts to the factory default for a
single power cycle.
All user files and settings (drivers, audio
and video adjustments, IP settings, and so
on) are maintained.
NOTE:
firmware or perform a mode 1 reset by
mistake, cycle power to the device to
return to the firmware version running
prior to the reset.
IP settings revert to factory defaults.
Reset
button
Port mapping reverts to factory default.
Reset
DHCP turns off.
IP address is set to 192.168.254.254.
Reset LED blinks four times in quick
succession during reset.
Reset
The device reverts to the factory defaults
button
except for firmware.
Mode 4 results are performed.
All user modifiable configurations reset to
default values including IP settings and
real-time adjustments.
All user loaded files are deleted.
The Reset LED blinks 4 times in quick
succession during the reset.
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation
Result
If you do not want to update the
Purpose/Notes
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Use mode 4 to reset
all IP settings back to
factory defaults.
Use mode 5 to restart
with the default
configuration. This
is equivalent to SIS
ZQQQ
command
.
This reset also removes
the initial serial number
password and sets it to
no password.
48