Audio Dsp Sis Commands - Extron electronics DTP2 CrossPoint 82 User Manual

Scaling presentation switchers
Hide thumbs Also See for DTP2 CrossPoint 82:
Table of Contents

Advertisement

Audio DSP SIS Commands

DSP SIS command structure
Several digital signal processor (DSP) functions can be configured using SIS commands.
Commands entered via PCS are also displayed on the host communication utility screen
that is being used for SIS commands (for example, Extron DataViewer).
NOTE: These commands apply only to the DTP2/XTP/HDBT output (output 2).
DSP control commands are a subset of the SIS commands with a specific structure.
For a Set command, the form of the command string is:
E <parameter ID><OID>*<value>AU }
where:
<OID> (Object ID) is a six-digit integer identifying the processor (see
Identification number (OID)
<Parameter ID> is a letter identifying the parameter.
<Value> is a number indicating the level being set for the parameter.
For a View (Get) command, the value parameter can be eliminated, so that the
command structure for viewing a single parameter is:
E <parameter ID><OID>AU }
The unit response to these commands begins with Ds. The response format is:
Ds<Parameter ID><OID>*<value> ]
DSP command symbol definitions
]
=
}
=
E
=
X10)
=
X11)
=
X11!
=
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control
on page 86).
Carriage return with line feed
Carriage return with no line feed
Escape
Object ID (OID) number
Gain value
Mute or Phantom power status
Object Identification number
See the
(OID)
table.
Levels use a 10x multiplier system with no decimal
places. For example, a level of +10.4 dB would be
104
entered as
and a level of -3.2 dB would be
-32
entered as
.
0 =
1
Disabled,
= Enabled
Object
89

Advertisement