Summary of Contents for Extron electronics DTP2 CrossPoint 82

  • Page 1 User Guide Scalers DTP2 CrossPoint 82 Scaling Presentation Switchers 68-3438-01 Rev. A 03 20...
  • Page 2: Safety Instructions

    Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad WARNING This symbol, , when used on the product, is intended to avvertire l’utente della presenza di tensione non isolata pericolosa alert the user of the presence of uninsulated dangerous voltage within the all’interno del contenitore del prodotto che può...
  • Page 3 Copyright © 2020 Extron Electronics. All rights reserved. www.extron.com Trademarks All trademarks mentioned in this guide are the properties of their respective owners. The following registered trademarks ( ® ), registered service marks ( ), and trademarks ( ) are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on the...
  • Page 4 FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5: Conventions Used In This Guide

    Conventions Used in this Guide Notifications The following notifications are used in this guide: CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure. ATTENTION: Risk of property damage. • • Risque de dommages matériels. NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make working with the application easier.
  • Page 7: Table Of Contents

    Offline Device Preview ........98 Output Submenu .......... 37 Software Overview ..........99 Audio Submenu ..........40 Software Menu ..........99 Advanced Submenu ........42 Device Menu..........102 Communications Submenu ......45 DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Contents...
  • Page 8 RS-232 Panel ..........112 Reference Information ......113 Mounting ............113 Tabletop Mounting ........113 Rack Mounting ........... 113 Downloading Updated Firmware ..... 114 Licensed Third-Party Software Used in the Switchers ............115 DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Contents viii...
  • Page 9: Introduction

    HDMI loop-out. The switchers can be controlled and configured via Ethernet, RS-232, or USB. The DTP2 CrossPoint 82 IPCP SA and IPCP MA 70 models each have a built-in Extron IPCP Pro 355M Control Processor, and an integrated class D power amplifier.
  • Page 10: Models

    (such as the DTP T USW 333) at a conference table, lectern, or wall. It can also be integrated into an XTP CrossPoint matrix switcher system. Output —The DTP2 CrossPoint 82 can transmit to a DTP or DTP2, XTP, or HDBaseT •...
  • Page 11: Audio Integration Capabilities And Available Power Amplifiers

    Matrix switcher integration In addition to supporting DTP endpoints, the DTP2 CrossPoint 82 can be integrated into an XTP CrossPoint matrix switcher system. This enables facility-wide AV system applications with a centralized AV signal distribution infrastructure, as well as several presentation spaces with local AV switching and processing.
  • Page 12 • 1 x 100 watts @ 70 volts DTP2 CrossPoint 82 power amplifiers feature an advanced Class D amplifier design with Class D Ripple Suppression (CDRS), an Extron-patented technology that provides a smooth, clean audio waveform and an improvement in signal fidelity over conventional Class D amplifier designs.
  • Page 13 Four Digital I/O ports — Allows for interfacing with other systems in the room. • Four relays for controlling room functions — Enables control of lighting, screen settings, and other device functions. • eBUS port for connecting eBUS button panels and accessories DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Introduction...
  • Page 14 Integrated DTP2 extension supports transmission of video, audio, and control up to 330 feet (100 meters) over a shielded CATx cable. Extron XTP DTP 24 shielded twisted pair cable is strongly recommended for optimal performance. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Introduction...
  • Page 15 — Enables mixing and matching with desktop and wallplate endpoints, as well as other DTP and DTP2-enabled products to meet application requirements. The DTP2 CrossPoint 82 presentation matrix switcher can be integrated with XTP and XTP II CrossPoint matrix switchers to provide connectivity between presentation spaces and a larger, facility-wide system.
  • Page 16 • Internal video test patterns and pink noise generator for calibration and setup — The DTP2 CrossPoint 82 provides several video test patterns and audio pink noise to facilitate proper system setup and calibration of display devices. •...
  • Page 17 HDMI sources. Output Standby Mode — The DTP2 CrossPoint 82 can be set to automatically mute • video and sync output to the display device when no active input signal is detected.
  • Page 18: Setup And Configuration Methods

    Extron Everlast Power Supply is covered by a 7-year parts and labor warranty. • Setup and Configuration Methods Control the DTP2 CrossPoint 82 switchers using one or more of the following methods: • The front panel controls and the on-screen display (OSD) menu (see...
  • Page 19: Application Diagrams

    Application Diagrams The following diagrams show examples of typical applications for the DTP2 CrossPoint 82. AV LAN Extron Ethernet SM 26 Extron Control Facility/Room Speakers Wireless Access Point Control App for Pro Series Control Systems Corporate Boundary Microphones Ethernet Ethernet...
  • Page 20 FLAT PANEL 4K Display AUDIO IN HDMI IN HDMI Laptop Extron Local 4K Monitor DTP T HWP 4K 231 D Transmitter Figure 2. DTP2 CrossPoint 82 IPCP MA 70 Application Example DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Introduction...
  • Page 21: Installation

    Installation This section contains information on how to connect cables to the DTP2 CrossPoint 82 models. Topics in this section include: • Installation Overview • Rear Panel Connections Connection Details • • Twisted Pair Recommendations for DTP, XTP, and HDBT Communication Installation Overview Turn off or disconnect all related equipment.
  • Page 22: Rear Panel Connections

    Rear Panel Connections Figures 3 through 5 show the rear panels of the three DTP2 CrossPoint 82 models. INPUTS ( DTP2/XTP) OUTPUTS ( DTP2/XTP/HDBT) AUDIO INPUTS OUTPUTS REMOTE 100-240V 1.0A MAX HDMI HDMI HDMI +48V LINK LINK LINK OVER TP...
  • Page 23 Consumer Electronics Control (CEC) — CEC control commands control basic control functions such as power on and off, input switching, volume, and mute. The DTP2 CrossPoint 82 can issue CEC commands to a display device through the HDMI and DTP2 ports.
  • Page 24 NOTE: RS-232 communication can also be sent to the far end of the twisted pair connection, but it must be done through RS-232 insertion via Ethernet. A control signal applied to a DTP2 CrossPoint 82 LAN or AV LAN port can be routed to Ethernet to RS-232...
  • Page 25 Ne pas étamer les câbles. Les câbles étamés ne sont pas aussi bien fixés dans les terminaisons des connecteurs à vis captives et pourraient sortir. LAN connector (DTP2 CrossPoint 82 base model only) — To control the DTP2 CrossPoint 82 base model through Ethernet, connect a LAN or WAN to this RJ-45 LAN connector.
  • Page 26 Receive (Rx) Transmit (Tx) Transmit (Tx) Figure 7. RS-232 Wiring Reset LED — This green LED remains lit while the DTP2 CrossPoint 82 has power. While the button (see , below) is being pressed and held, this LED blinks every Reset...
  • Page 27 To ensure the control processor LAN and AV LAN connections (ports) are connected to separate networks, the LAN and AV LAN IP address schemes must be on different subnetworks. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation...
  • Page 28: Connection Details

    LAN port — Single Ethernet connector. The DTP2 CrossPoint 82 base model has a LAN connector to the left of the Remote RS-232 connector (see figure 3, , on page 14) instead of the LAN and AV LAN ports on the IPCP models (see figures 4 eBUS port —...
  • Page 29: Hdmi Connections

    (top mounted). Two HDMI cables can also be attached to one side mounted bracket (stack mounted). Top Mounted Side Mounted Stacked Figure 10. LockIt Bracket Mounting Orientations DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation...
  • Page 30 The DTP2 CrossPoint 82 HDMI connectors require the LockIt brackets to be mounted as follows: • HDMI inputs 2, 4, and 6 — Side mounted. Can be stacked with the connectors below them. • HDMI inputs 3 and 5, HDMI Loop Out — Stack mounted. Because these connectors...
  • Page 31: Twisted Pair Recommendations For Dtp, Xtp, And Hdbt Communication

    Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles. Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners. • • Separate twisted pair cables from AC power cables. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation...
  • Page 32: Operation

    • RS-232 and IR Signal Insertion Front Panel Overview The DTP2 CrossPoint 82 front panel features differ from each other as follows (see the legend on the next page): both DTP2 CrossPoint 82 IPCP models have IPCP Pro 355 Control Processors, while DTP2 CrossPoint 82 base model does not. The two IPCP models have identical front panels, except for their product names.
  • Page 33 NOTE: To configure logo key effects (such as RGB keying, alpha keying, and so on), you must use PCS (see the DTP2 CrossPoint 82 Help File). Output selection buttons (1 and 2) — Press one of these buttons to select the output on which the selected input is displayed.
  • Page 34: Powering Up

    Volume (configurable, see the DTP2 CrossPoint 82 PCS Help File for more information). The eight LED indicators for each knob light according to the level being adjusted. The LEDs light in order from bottom to top to indicate steps from 0% to 100% of the set limits.
  • Page 35: Selecting An Input

    The on-screen menu has a default timeout of 60 seconds. • • The screen examples shown in this section show the OSD screens of an DTP2 CrossPoint 82 IPCP SA. The OSD for your product may differ slightly. Menu Selection Buttons MENU ENTER Figure 16.
  • Page 36: Menu Overview

    Figure 17. On-screen Menu Example The on-screen menu contains eight submenus with various submenu items of adjustable settings or device information (see the Submenu Items table on the next page. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 37: Using The Menu Screens

    (see the example at right). Press Enter to select the item. Press the ƒ button to return to the list of submenus in the left panel. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 38: Device Info Screen

    The read-only Device Info screen is listed first in the submenus (left) panel. This screen contains information about your DTP2 CrossPoint 82, including unit name, firmware version, internal temperature in Celsius and Fahrenheit, and format and signal information for the selected input device, all outputs, and the loop out.
  • Page 39: Quick Setup Submenu

    IP Address — Press the ƒ and „ buttons to switch between octets. Press the > < buttons to change the value of a selected octet. The default address is 192.168.254.254. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 40: Picture Controls Submenu

     buttons, as indicated by the blue up and down  the vertical size, press the arrows after the V setting. to return to the OSD menu. When finished, press Enter DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 41 Detail — Press the < buttons to adjust the image sharpness. The range is through . The default is Press Enter or ƒ to select the changes and return to the submenu. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 42: Input Submenu

    HDCP Authorized — This feature determines if a digital input reports as an HDCP authorized sink to a source. Select this item to enable or disable HDCP communication by selecting whether the DTP2 CrossPoint 82 input reports to the source as an ...
  • Page 43 Capture EDID — Select this item to capture the EDID of the sink device attached to an output and save it to one of the 10 custom EDID slots. The DTP2 CrossPoint 82 assigns the captured EDID to its selected input. To capture an EDID:...
  • Page 44 **Rates supported only with 4:2:0 color sampling on an input in DTP or XTP mode. 4:4:4 sampling supported from DTP2 transmitters or on DisplayPort or HDMI inputs only. ***4096x2160 rates are available only for output resolution and cannot be selected for input EDID. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 45: Output Submenu

    Output Rate — Select this item to specify the output resolution and refresh rate. The • DTP2 CrossPoint 82 switchers have a range of resolutions from which to choose (see Output Resolutions and Refresh Rates table on the next page for the available settings).
  • Page 46 Auto (based on the EDID of the sink) (default) • DVI RGB 444 HDMI RGB 444 Full • • HDMI RGB 444 Ltd • HDMI YUV 444 Ltd • HDMI YUV 422 Ltd DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 47 User Image — Displays a user-uploaded image. To upload images, use the PCS • software Logo screen (see the DTP2 CrossPoint 82 Help File for instructions). • Loop Out — Lets you select the input for the unscaled, looped output. Press Enter ...
  • Page 48: Audio Submenu

    All audio outputs are muted. None Analog Audio Analog Utilizes analog Aux input for inputs 1 through 6. Utilizes DTP2 Tx analog input for inputs 7 and 8. Sets the selected input to analog. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 49 Use PCS to configure DSP and other audio parameters for the audio inputs and • outputs (see the DTP2 CrossPoint 82 PCS Help File for detailed instructions). • Use SIS commands to configure non-DSP audio parameters (see the commands Audio Configuration starting on page 75).
  • Page 50: Advanced Submenu

    By default all test patterns include a single pixel wide crop pattern line. • The Audio Test pattern displays a crop pattern and also outputs pink noise at 48 kHz, 24 bit. • Test pattern selections persist through a power cycle. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 51 The location of this image on the screen can be adjusted using SIS commands (see the Horizontal Shift (Logo) Vertical Shift (Logo) commands on page 72) or PCS (see the DTP2 CrossPoint 82 PCS Help File). Press to confirm your selection. Enter...
  • Page 52 • INn: Auto Memory — Enables or disables Auto Memory. When Auto Memory is set to On (default), the DTP2 CrossPoint 82 stores the current input configuration and picture control values. The switcher stores 32 auto memories per input, with input configuration and picture control data for each video resolution.
  • Page 53: Communications Submenu

    Gateway — Press the buttons to select an octet of the gateway address.  > Press the < buttons to adjust the value of the selected octet. The default is 0.0.0.0. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 54: Front Panel Lockout (Executive Modes)

    Front Panel Lockout (Executive Modes) The DTP2 CrossPoint 82 switchers have five modes of front panel security lock that limit the operation of the device from the front panel. When the front panel controls are locked, RS- 232, USB, and Ethernet control remain operational.
  • Page 55: Tie Presets

    • Detail Saving a preset when using a matrix switcher When using the DTP2 CrossPoint 82 with a matrix switcher, do the following to save a preset: Switch each input of the matrix to the DTP2 CrossPoint 82. Configure each input: size, position, detail, brightness, and contrast.
  • Page 56 • All user loaded files are deleted. password and sets it to no password. • The Reset LED blinks 4 times in quick succession during the reset. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
  • Page 57: Rs-232 And Ir Signal Insertion

    Insertion) — A control • signal applied to the DTP2 CrossPoint 82 LAN port can be routed to the RS-232 port of any connected twisted pair device. The RS-232 insert inputs and outputs inserted via Ethernet can support up to a 115K baud rate.
  • Page 58: Ethernet To Rs-232 Insertion

    Figure 31 is an example of an Ethernet to RS-232 insertion, in which an Extron controller provides control of an HD camera via the DTP2 CrossPoint 82 and a DTP HDMI 4K 230 transmitter. Configure this type of insertion as follows: Connect a TP cable from the control system to the switcher LAN port, directly or via a network.
  • Page 59: Captive Screw Ir Signal Insertion

    Changing the starting point By default the UART start point is 2000. You can change the starting port number by any of the following methods: Using the Product Configuration Software (see DTP2 CrossPoint 82 PCS Help file) • • Using SIS commands (see the command to Set UART start point on page 81)
  • Page 60 Connect the COM (serial) port of the control system to the Over TP IR captive screw port (output port 2 in this example). Connect the TP cable from the DTP2 CrossPoint 82 RJ-45 Out connector to the DTP input of the endpoint.
  • Page 61: Sis Configuration And Control

    SIS Configuration and Control The DTP2 CrossPoint 82 switchers can be configured and controlled via Extron Simple Instruction Set (SIS) commands when connected to a host computer or other device (such as a control system). Attach the host device to the rear panel RS-232 connector or LAN connector, or to the front panel USB port.
  • Page 62: Password Messages

    The prompt requires a password, followed by a carriage return. The prompt is repeated if the correct password is not entered. • For initial setup: On the rear panel of the DTP2 CrossPoint 82, a label is attached containing the following: The factory-configured passwords for all accounts on this device have been set to the device serial number.
  • Page 63: Error Responses

    ASCII. ASCII to Hex Conversion Table Space • Figure 33. ASCII to Hexadecimal Character Conversion Table DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 64: Symbol Definitions

    Audio output connector = HDMI 1 selection = TP 2 = Over DTP Analog = Line Out 1 = Line Out 2 = Line Out 3 = Line Out 4 DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 65 Vertical = to two times the maximum supported output resolution Response is five digits, padded with zeros. EDID file 128 or 256 bytes of binary data DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 66 ***4096x2160 rates are available only for output resolution and cannot be selected for input EDID. ****4:4:4 color sampling at these scaled output rates is available only to a DTP2 Rx. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 67 For example: X! *\ Command: Vtyp X! * X#] Response: (untagged) DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 68 = Encrypt output (with a maximum of 10 seconds of authentication trials. = Follow input (with continuous authentication trials). = Encrypt output (with continuous authentication trials). DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 69 When Input 7 or 8 is set to DTP mode, the switcher uses analog audio from the remote DTP transmitter instead of analog audio from the rear panel of the unit. Analog and Auto formats are not allowed on inputs 7 and 8 of the DTP2 CrossPoint 82 when it is set to XTP mode.
  • Page 70 = RGB key = Level key = Alpha key Audio playback file slot number through Highest priority for playback is slot 1, descending to lowest priority slot 16. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 71 (Example: DTP2-CrossPoint-82-IPCP-SA-15-9E-B0 Subnet mask in CISG Prefix representing subnet mask bits (subnet mask value commands in CISG commands). Default = , which represents the default subnet mask, 255.255.255.0. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 72: Command And Response Tables For Sis Commands

    = DTP2/XTP/HDBT output 2 (scaled) 3 = HDMI/DVI Loop output 0 = No input signal detected = Input digital video format (view only) = DVI = HDMI = DisplayPort DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 73 Can contain up to 32 characters, excluding: = Input name (text label) (comma) , , and Video Input Default = • • Input EDID and Output Resolutions See the on page 58. = EDID emulation DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 74 1 = Fill — Each input rate fills the entire output raster (default). = Aspect ratio setting 2 = Follow — Each input rate is displayed with its native aspect ratio. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 75 = DisplayPort input 1 = HDMI or DVI input 2, 3, 4, 5, or 6 = DTP2/XTP input 7 or 8 = Aux audio input 0-127 = Picture adjustment (default = DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 76 X1& = Horizontal and vertical size • Horizontal = to two times the maximum supported output resolution • Vertical = to two times the maximum supported output resolution DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 77: Output Configuration

    Input EDID and Output Resolutions on page 58. = EDID emulation = Output video mute = Unmute video = Mute video to black screen = Mute video and sync DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 78 = Lowest power state — TP remote power and over TP functions are disabled. 2 = Low power state — Over TP and TP remote power are enabled. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 79 = User logo number through . The response is three digits padded with leading zeros. = Logo disabled No Signal user logo is displayed. HDCP = A user-assigned logo is displayed. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 80 = User logo number through . The response is three digits padded with leading zeros. = No signal, screen saver user logo or image is displayed. = User HDCP logo displayed DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 81 = Blue of RGB key (available only when = Level key (available only when = Key effect setting through = Key effect = Disable, = Transparency, = RGB key, = Level key, = Alpha key DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 82 = On or enabled = Preset name (text label) Up to 32 characters, excluding (comma) , , and = Input preset number through . Response is three digits, padded with zeros. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 83 Aux* Line input when digital is not present.. On the DTP2 CrossPoint 82, when Input 7 or 8 is set to DTP mode, the switcher uses analog audio from the remote DTP transmitter instead of analog audio from the rear panel of the DTP2 CrossPoint 82.
  • Page 84 View the repeat mode set for slot KEY: = Playback slot number through Highest priority for playback is slot 1, descending to lowest priority 16. = Repeat play = No repeat, = Repeat DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 85 Number of seconds to wait before repeating playback on the current = Playback delay audio file, if repeat has been enabled. through (1-300 seconds delay between repeats). = No delay DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 86 = Video signal status = Video, TMDS, or DP signal not detected = Video, TMDS, or DP signal detected DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 87 HDCP user logo is visible only if a single HDCP non-compliant display is attached, or if both attached displays are non-HDCP compliant. If the DTP2 CrossPoint 82 is connected to one compliant and one non-compliant display at the same time, only a green or black screen with no text or logo appears on the non-compliant display.
  • Page 88 Absolute system reset, retain Same as absolute system reset IP settings ZQQQ ) except that IP address, subnet mask, gateway address, DHCP, and port mapping are not reset. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 89 = Configuration type = IP configuration (ip.cfg) = Unit-specific parameters (box.cfg) /nortxe-backup Save Configuration files are stored in the directory , created on the unit by the command. NOTE: DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 90 IPCP 355M, Mono Amplifier • • • • • • • • = Video output mute = Unmuted = Muted to black screen = Muted video and sync DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 91 Leading zeros in each of the four octets are optional in setting values, and are suppressed in returned values. 0.0.0.0 nnn.nnn.nnn.nnn ( = Gateway address = default) 255.255.255.0 nnn.nnn.nnn.nnn ( = Subnet mask = default) DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 92 = Hardware (MAC) address Prefix representing subnet mask bits (subnet mask value in CISG = Subnet mask in CISG commands commands). Default = , which represents the default subnet mask, 255.255.255.0. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 93 If the admin password is cleared, the user password is cleared also. A user password cannot be assigned if no administrative password exists. An error code is returned. NOTE: DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 94: Audio Group Master Sis Commands

    60002 Line Output 3 60008 DTP2/XTP/HDBT R 60003 Line Output 4 60009 DTP Analog L 60004 Amp L or Mono 60010 DTP Analog R 60005 Amp R 60011 DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 95 1 Mic Volume 3 Program Volume 5 Line Volume 7 Bass 9 Output Volume 2 Mic Mute 4 Program Mute 6 Line Mute 8 Treble 10 Output Mute DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 96 Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply = Increment or decrement value by 10. For mute values, use 0 or 1 as the value. X10& = Group master mute status = unmuted = muted DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 97: Audio Dsp Sis Commands

    For example, a level of +10.4 dB would be entered as and a level of -3.2 dB would be entered as X11! Mute or Phantom power status Disabled, = Enabled DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 98 +10.4 dB would be entered as and a level of -3.2 dB would be entered as X11! = Mute or Phantom power status Disabled = Enabled DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 99: Cec Sis Commands

    Example: %2A%07%FF X21) = CEC address byte — In the form of percent sign followed by two hex digits Example: = Extron output ( ) to TV ( DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 100 Example: %2A%07%FF X21) = CEC address byte In the form of a percent sign followed by two hexadecimal digits Example: %E0 = Extron output (14) to TV (0) DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 101 Example: %2A%07%FF X21) = CEC address byte In the form of a percent sign followed by two hexadecimal digits Example: %E0 = Extron output (14) to TV (0) DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
  • Page 102: Configuration Software

    To download PCS from the Extron website, locate it on the Download Center page or go to the PCS product page. Software Download Center Page Figure 34. Download Center Page on the Extron Website DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 103 C:\Program Files (x86) \ Extron \ DTP2 CrossPoint 82. If there is not already an Extron folder in your Program Files (x86) folder, the installation program creates it as well. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 104: Software Connection

    Click the Apply and Connect button to accept the changes and connect to the • selected device. A new device configuration tab opens. Click the Cancel button to cancel any pending changes and return to the Device • Discovery panel. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 105: Tcp/Ip Panel

    To connect indirectly to a device through a control processor via an AV LAN: If your DTP2 CrossPoint 82 is connected to an AV LAN, you can connect to it through a control processor such as an Extron IPCP, as follows:...
  • Page 106: Offline Device Preview

    Select the desired device model from the Device Models list (see figure 39, ). In figure 39, DTP2 CrossPoint 82 IPCP SA was selected. Click the Configure button ( ). A new offline device configuration tab opens. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 107: Software Overview

    Software Overview NOTE: For details about specific software features, see the DTP2 CrossPoint 82 PCS Help file. Figure 40. PCS Main Window Each device screen has a Device drop-down menu for configuration options. The Software menu contains software configuration and information options.
  • Page 108: Software Settings

    Click the OK button to close the dialog box. Extron PCS Help This options opens the PCS help file for general PCS operations. From the Software menu, select Extron PCS Help. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 109 If necessary, click the Close Session(s) and Exit button (see figure 45, ) to disconnect the software from connected devices, close all offline device tabs, and close the software. Click the Cancel button ( ) to leave the software open. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 110: Device Menu

    PC. This exported configuration can be saved as a backup file (with a .extz extension), or used to replicate settings from one device to other devices of the same model. When restoring a configuration, you can select specific device settings. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
  • Page 111 Update Firmware to Multiple Devices... — Uploads firmware to multiple devices on the network. NOTE: The connected devices must be connected via LAN. DTP2 CrossPoint 82 <model name> Help — Opens the DTP2 CrossPoint 82 PCS • Help file in a separate window.
  • Page 112: Internal Web Page

    The DTP2 CrossPoint 82 switchers feature an internal web server, displayed as a web page. This page allows you to monitor and adjust certain settings of the DTP2 CrossPoint 82 via a LAN or WAN connection. Use a web browser to view the pages on a PC connected to the switcher LAN port.
  • Page 113: Disabling Compatibility Mode

    Figure 48 on the previous page shows the web page for a DTP2 CrossPoint 82 IPCP SA model. The pages for the other DTP2 CrossPoint 82 models are identical except for the product name in the Device Info panel, and the Inputs panel.
  • Page 114: Device Info Panel

    To view the status and type of all inputs, click the link (named 7 More) in the lower-left corner of the Inputs panel to view the Inputs dialog box (see figure 50 on page 107 for an example). DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Internal Web Pages...
  • Page 115: Roles And Permissions Panel

    Passwords are case-sensitive. A user password cannot be assigned if no administrator password exists. • • If the Admin password is cleared, the user password is cleared as well. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Internal Web Pages...
  • Page 116: Setting A Password

    To remove an assigned password: In the field, enter a single space. Change Admin Password Change User Password Enter a single space in the appropriate field. Confirm Password Click Save DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Internal Web Pages...
  • Page 117: Device Status Panel

    Celsius. Syncing the DTP2 CrossPoint 82 to the PC To set the DTP2 CrossPoint 82 date and time to match that of your computer: at the bottom of the Device Status panel. When the sync is completed,...
  • Page 118: Outputs Panel

    The following status symbols may be displayed for connected outputs: Symbol Definition The display is HDCP compliant. The display is not HDCP compliant. No Display No display is connected. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Internal Web Pages...
  • Page 119: Firmware Panel

    The Firmware panel (see figure 48, ) displays the current firmware version and the date it was last updated. You can also update the firmware on your DTP2 CrossPoint 82 from this panel (firmware files can be downloaded from www.extron.com, see...
  • Page 120: Network Settings Panel

    , on page 104), you can set the IP address, subnet mask, and gateway address for your DTP2 CrossPoint 82, and turn DHCP on and off. You can also view the MAC address of the unit. To set the IP addresses: Click Edit in the lower-left corner of the Network Settings panel.
  • Page 121: Reference Information

    Attach the provided rubber feet to the bottom four corners of the enclosure. Rack Mounting The DTP2 CrossPoint 82 can be rack-mounted using the preinstalled rack ears brackets. UL guidelines for rack mounted devices The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the switcher in a rack.
  • Page 122: Downloading Updated Firmware

    ) in the Downloads column and click it. Move the pointer to the Firmware link ( Figure 59. D Link on Firmware Download Center Page On the Download Center screen, click the D link (see figure 59, DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Reference Information...
  • Page 123: Licensed Third-Party Software Used In The Switchers

    About - Extron PCS dialog box. • IPCP Pro 355M web page — For DTP2 CrossPoint 82 IPCP models, you can view details about third-party packages and associated licensing used by the IPCP control processor by clicking the License Information button on the internal web pages of the IPCP Pro 355M control processor.
  • Page 124 GNU LGPL v2.1 GNU LGPL v2.1 libcurl socat GNU GPL v2 libdaemon GNU GPL v2.1 spawn-fcgi libdnet sqlite public domain libgpg GNU LGPL v2.1 xinetd custom libpcap zlib zlib libpng libpng license DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Reference Information...
  • Page 125: Extron Warranty

    Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.

Table of Contents