Summary of Contents for Extron electronics DTP T DSW 4K Series
Page 1
User Guide Video Products DTP T DSW 4K Series DTP Switchers 68-2761-01 Rev. C 01 19...
Page 2
Safety Instructions Istruzioni di sicurezza • Italiano Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to Questo simbolo, ,quando viene utilizzato il prodotto, serve AVVISO: alert the user of the presence of uninsulated dangerous voltage within ad avvisare l’utente della presenza di tensioni pericolose non isolate the product’s enclosure that may present a risk of electric shock.
Page 3
安全記事 • 繁體中文 안전 지침 • 한국어 警 告 경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는 若產品 上使 用此 符 號 , 是 為了提 醒 使 用者,產品 機 殼內 存 在 著 접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 可能會導致觸電之風險的未絕緣危險電壓。...
Page 4
, and trademarks (TM) are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com): Registered Trademarks (®) AVTrac, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, FlexOS, Global Configurator, Global Scripter, GlobalViewer, Hideaway, Inline, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,...
Page 5
Conventions Used in this Guide Notifications The following notifications are used in this guide: CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure. ATTENTION: • Risk of property damage. • Risque de dommages matériels. NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make working with the application easier.
Introduction This guide describes the function, installation, and operation of the DTP T DSW 4K series of switchers. Unless otherwise stated, the terms “switcher” and “transmitter” are used interchangeably in this guide to refer to all of the products in the series.
RS-232 and unidirectional IR signals to an HDBaseT-enabled display. • Accepts additional analog stereo audio signals — The DTP T DSW 4K series accepts stereo analog audio signals for simultaneous transmission over the same shielded twisted pair cable.
• L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement. The DTP T DSW 4K series can be placed on a table, mounted in a rack, or mounted under a desk or table. Tabletop Use Affix the included rubber feet to the bottom of the unit and place it in any convenient location.
Input signal LEDs — Light green when a signal is detected on the associated input. Input HDCP LEDs — Light green when HDCP presence is detected on the associated input. Extron DTP T DSW 4K Series • Installation and Operation...
DTP/HDBaseT output DC power input connector — Wire and connect the included external 12 VDC 2 A power supply into this 2-pole connector. The DTP T DSW 4K series can provide remote power to a compatible receiver (see Power Supply Wiring on page 9).
Page 12
Tx Rx 232 port (see figure 4 for wiring instructions). IR Device Tx/Rx Pins RS-232 Device Figure 4. Over TP Port Wiring NOTE: RS-232 and IR data can be transmitted simultaneously. Extron DTP T DSW 4K Series • Installation and Operation...
Page 13
(see figure 5 for wiring instructions). TALLY OUT Ground Receive pin on connected unit Transmit pin on connected unit CONTACT IN REMOTE Black Figure 5. RS‑232, Contact, and Tally Connector Wiring “Show Me” Cable Extron DTP T DSW 4K Series • Installation and Operation...
Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles. • Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners. • Separate twisted pair cables from AC power cables. Extron DTP T DSW 4K Series • Installation and Operation...
• The DTP T DSW 4K series can only transmit remote power. It cannot receive remote power from a locally powered receiver. • Remote power is only available when the unit is set to DTP mode. When the unit is set to HDBaseT mode, remote power and analog audio are disabled.
Page 16
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. • Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération ou dans les cavités murales. Extron DTP T DSW 4K Series • Installation and Operation...
Last character cannot be a hyphen (-) Default is model name 128 or 256 byte EDID raw HEX Video color bit depth 0 = auto, based on EDID of sink (default) 1 = force 8-bit Extron DTP T DSW 4K Series • SIS Commands...
Page 19
(Continuous trials for HDMI sinks, attempt for 10 seconds on DVI sinks,then fail) Encrypt as required by input (Continuous trials for HDMI sinks and DVI sinks) Always encrypt (Continuous trials for HDMI sinks and DVI sinks) Extron DTP T DSW 4K Series • SIS Commands...
The TMDS output format resumes as configured when the source signal changes to a signal other than 4K/UHD @ 60 Hz with YUV 4:2:0. Extron DTP T DSW 4K Series • SIS Commands...
0 = disabled (default) 1 = enabled (highest active input has priority) 2 = enabled (lowest active input has priority) X2) = DTP/HDBaseT switch Position 0 = DTP mode (default) 1 = HDBaseT mode Extron DTP T DSW 4K Series • SIS Commands...
Page 23
X1@ = Pixel Phase 0 to 63 (32 is default) X1# = Total pixels ±255 of the default value (depends on input rate) X1$ = Horizontal/Vertical start 0 to 255 (128 is default) Extron DTP T DSW 4K Series • SIS Commands...
Page 24
X1( = Embedded audio format HDMI and DisplayPort: auto (default) force existing digital/embedded audio force embedded analog audio VGA: disable embedded DVI format audio (default) 1 = enable embedded audio (HDMI format) Extron DTP T DSW 4K Series • SIS Commands...
Page 25
(Continuous trials for HDMI sinks, attempt for 10 seconds on DVI sinks,then fail) Encrypt as required by input (Continuous trials for HDMI sinks and DVI sinks) Always encrypt (Continuous trials for HDMI sinks and DVI sinks) Extron DTP T DSW 4K Series • SIS Commands...
Page 26
Up to 24 alphanumeric characters (including hyphen [-]) X* = 128 or 256 byte EDID raw HEX X1! = Native resolution and refresh rate from selected EDID Example: 1920x1200 @ 60Hz Extron DTP T DSW 4K Series • SIS Commands...
Page 27
1 = enabled (highest active input has priority) 2 = enabled (lowest active input has priority) X1& = Verbose mode clear/none verbose mode (default) tagged responses for queries verbose mode and tagged responses for queries Extron DTP T DSW 4K Series • SIS Commands...
Page 28
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Need help?
Do you have a question about the DTP T DSW 4K Series and is the answer not in the manual?
Questions and answers