Extron electronics DTP2 CrossPoint 82 User Manual page 25

Scaling presentation switchers
Hide thumbs Also See for DTP2 CrossPoint 82:
Table of Contents

Advertisement

Analog audio line input connectors 3 and 4 — Connect line level analog audio
H
sources to audio input connectors 3 and 4 on the 5-pole captive screw connector
for balanced or unbalanced stereo
Connectors are included with the unit, but the audio cable is not (see
page 20 for wiring).
Analog audio mic/line input connectors 1 and 2 and adjacent Power LEDs—
I
Connect balanced or unbalanced mic or line level inputs to these 3-pole Mic/Line
captive screw connectors These inputs support optional +48 VDC phantom power,
which is indicated by the LEDs at the left of the connectors.
Analog audio line output connectors 1 through 4 — Connect balanced or
J
unbalanced analog audio output devices to one or both 5-pole captive screw audio
output connector pairs 1 and 2 or 3 and 4 (see
page 20). These connectors are configurable as four discrete mono outputs or two
stereo inputs.
ATTENTION:
For unbalanced audio, connect the sleeves to the ground contact. Do not
connect them to negative (–) contacts.
Pour l'audio asymétrique, connectez les manchons au contact au sol. Ne
PAS connecter les manchons aux contacts négatifs (–).
The length of the exposed wires in the stripping process is critical. The ideal
length is 3/16 inch (5 mm). If the exposed portion is longer, the wires may
touch, causing a short circuit between them. If the exposed wires are shorter,
they can be easily pulled out, even if tightly fastened by the captive screws.
La longueur des câbles exposés est primordiale lorsque l'on entreprend
de les dénuder. S'ils sont un peu plus longs, les câbles exposés pourraient
se toucher et provoquer un court circuit. S'ils sont un peu plus courts, ils
pourraient sortir, même s'ils sont attachés par les vis captives.
Do not tin the wires. Tinned wire does not hold its shape and can become
loose over time.
Ne pas étamer les câbles. Les câbles étamés ne sont pas aussi bien fixés
dans les terminaisons des connecteurs à vis captives et pourraient sortir.
LAN connector (DTP2 CrossPoint 82 base model only) — To control the DTP2
K
CrossPoint 82 base model through Ethernet, connect a LAN or WAN to this RJ-45 LAN
connector. Ethernet control allows you to configure and control the switcher from a
remote location via SIS commands, the PCS software, or the embedded web pages.
NOTE: For the IPCP models, connect a LAN or WAN to any of the AV LAN
connectors or to the LAN connector on the IPCP Pro control processor (see
page 18).
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation
(see
figures 3 through
or dual mono audio
Analog Audio Connections
5).
figure 9
on
on
on
Q
17

Advertisement