Extron electronics DTP2 CrossPoint 82 User Manual page 96

Scaling presentation switchers
Hide thumbs Also See for DTP2 CrossPoint 82:
Table of Contents

Advertisement

Group Master SIS Command and Response Table
Command
Audio Group Master
View Group Master
View soft limits
Group Master Value
Set a group fader value
Example:
View group fader value
Increment a group fader
value
Example:
Decrement a group fader
value
Mute a group
Unmute a group
View group mute status
KEY:
X10)
= Object ID (OID) number
X10!
= Group master group number
X10#
= Soft limit high value in dB
X10$
= Soft limit low value in dB
X10%
= Group master value
X10^
= Increment or decrement value
X10&
= Group master mute status
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
E L X10! GRPM }
X10# * X10$]
In verbose modes 2 and 3:
GrpmL X10! * X10# * X10$]
E D X10! * X10% GRPM }
GrpmD X10! * X10%]
E
}
D3*-293GRPM
GrpmD3*-293
E D X10! GRPM }
X10%]
In verbose modes 2 and 3:
GrpmD X10! * X10%]
E D X10! * X10^ +GRPM } GrpmD X10! * X10%]
E
}
D3*30+GRPM
GrpmD3*-263
E D X10! * X10^ –GRPM } GrpmD X10! * X10%]
E D X10! *1GRPM }
GrpmD X10! *1 ]
E D X10! *0GRPM }
GrpmD X10! *0 ]
E D X10! GRPM }
X10&]
In verbose modes 2 and 3:
GrpmD X10! * X10&]
See
1
through
Preconfigured group. Can alternatively be an alias, which is the
user-defined group name enclosed in braces (
The valid range for
grouped in
The valid range for
grouped in
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply
by 10. For mute values, use
Example: -100.0 dB through +80.0 dB is represented by
through
assigned to the group number (
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply
by 10. For mute values, use 0 or 1 as the value.
0
= unmuted
Additional Description
View low soft limit
limit
Set the level of group fader
X10%
]
Set group 3 fader control to
dB.
View the group fader value.
Increase the gain value of group
X10^
]
Raise the group 3 fader by 3 dB
from
example) to
Decrease the gain value of group
by
Mute all blocks in group
Unmute all blocks in group
View the group master mute status.
Object Identification number (OID)
10.
X10#
must be within the range for the gain block
X10!
.
X10$
must be within the range for the gain block
X10!
.
0
1
or
800
. The valid range depends on the type of gain block
X10!
1
= muted
X10$
and high soft
X10#
X10!
for group
.
X10!
.
-29.3
X10%
to
.
-29.3
dB (set in the previous
-26.3
dB.
X10^
X10%
to
.
X10!
.
X10!
on page 86.
{ }
).
.
-1000
).
to
X10!
by
X10!
.
88

Advertisement

Table of Contents
loading

Table of Contents