Extron electronics DTP2 CrossPoint 82 User Manual page 51

Scaling presentation switchers
Hide thumbs Also See for DTP2 CrossPoint 82:
Table of Contents

Advertisement

Screen Saver — Configures device behavior when no active input signal is detected.
Options include a black (default) or blue screen, or a user provided logo file. Optionally,
you can set a timeout to disable the output after a set duration to allow display devices
(such as a display screen or projector) to enter a lower power or standby state to
increase panel or lamp life.
To configure the screen saver:
1.
Select
Screen Saver
2.
Press the
or
button to select the screen saver type. The menu selections are:
Black (default)
Blue with the OSD message No Signal.
User Image — Displays an image that has been previously uploaded to
the unit. The location of this image on the screen can be adjusted using SIS
commands (see the
commands on page 72) or PCS (see the DTP2 CrossPoint 82 PCS Help File).
3.
Press
to confirm your selection.
Enter
NOTE: The switcher exits screen saver mode when the front panel
button is pressed, a video test pattern is activated, or an active input is detected.
If the unit is in front panel lock mode (see
Modes)
on page 46), pressing a front panel button exits the time-out but
access to any front panel controls or the menu system is disabled.
Screen Saver Timeout — Lets you specify the number of seconds the selected
screen saver is displayed before the output sync times out.
To set the sync timeout:
Select
Screen Saver Timeout
Press the
or
out. You can select a duration of
output sync times out. Select
never time out.
INn: Aspect Ratio — Sets the aspect ratio for the selected input to
fills the entire output raster) or
Fill mode — If you want to set an aspect ratio adjustment for a single input rate,
you can select the correct image size and position manually from the Picture
Controls submenu (Image Size and Position) (see
Submenu
starting on page 32).
Follow mode —Each input rate is displayed with its native aspect ratio (4:3, 5:4,
16:9, or 16:10) with the correct letter box or pillar box settings, visible under the
Image Size and Image Position items on the Picture Controls submenu.
If you want a single input to fill the screen in follow mode, you can manually set
the Image Position item on the Picture Controls submenu to 0,0 and set the
Image Size to match the current output rate
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation
from the Advanced menu and press
Horizontal Shift (Logo)
Front Panel Lockout (Executive
from the Advanced menu and press
button to select the amount of time before output sync times
(timeout is immediate) to
0
(501 seconds, the default) to set the sync to
Never
(follows the native aspect ratio of the input).
Follow
X
.
Enter
and
Vertical Shift (Logo)
or
Menu
Enter
seconds before the
500
(the default,
Fill
Picture Controls
,
.
Y
Enter
.
43

Advertisement

Table of Contents
loading