Twisted Pair Recommendations For Dtp, Xtp, And Hdbt Communication - Extron electronics DTP2 CrossPoint 82 User Manual

Scaling presentation switchers
Hide thumbs Also See for DTP2 CrossPoint 82:
Table of Contents

Advertisement

Twisted Pair Recommendations for DTP, XTP, and HDBT
Communication
Use the following pin configurations for shielded twisted pair cables used for DTP or
HDBaseT communication.
Figure 12.
Supported cables
The switchers are compatible with shielded twisted pair (F/UTP, SF/UTP, and S/FTP) cable.
ATTENTION:
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances and
reduce transmission errors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider:
Pin
TIA/EIA T568B
Wire Color
1
White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
6
Green
7
White-brown
8
Brown
Twisted Pair Cable Configuration
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the device with DTP transmitters or receivers.
N'utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d'Extron ou
le câble STP201 pour relier le appareil avec les émetteurs ou les récepteurs DTP.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000
XTP DTP 24P/1000
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use shielded couplers and punch down connectors.
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation
Pins:
12345678
Insert Twisted
Pair Wires
RJ-45
Connector
Non-Plenum 1000' (305 m) spool
Plenum 1000' (305 m) spool
Package of 10
23

Advertisement

Table of Contents
loading

Table of Contents