Summary of Contents for Extron electronics DTP2 CrossPoint 82
Page 1
DTP2 CrossPoint 82 Scaling Presentation Switchers User Guide Scalers 68-3438-01, Rev. D 04 24...
Page 2
Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad avvertire WARNING: This symbol, , when used on the product, is intended to l’utente della presenza di tensione non isolata pericolosa all’interno del alert the user of the presence of uninsulated dangerous voltage within the contenitore del prodotto che può...
Page 3
安全記事 • 繁體中文 안전 지침 • 한국어 警告: 경고: 이 이이 이 이이이 이이이 이이, 이이이 이이이이 이이 이이 이이이이 若產品上使用此符號, 是為了提醒使用者, 產品機殼內存在未隔離的危險 이이 이이이 이이이 이이 이이이이 이이이 이이이 이이이 이이이이이. 電壓, 可能會導致觸電之風險。 注意 若產品上使用此符號, 是為了提醒使用者, 設備隨附的用戶手冊中有重要 주의: 이 이이 이...
Page 4
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 5
Conventions Used in this Guide Notifications The following notifications are used in this guide: CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure. ATTENTION: • Risk of property damage. • Risque de dommages matériels. NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make working with the application easier.
HDMI loop-out. The switchers can be controlled and configured via Ethernet, RS-232, or USB. The DTP2 CrossPoint 82 IPCP SA and IPCP MA 70 models each have a built-in Extron IPCP Pro 355M Control Processor, and an integrated class D power amplifier.
• Output —The DTP2 CrossPoint 82 can transmit to a DTP or DTP2, XTP, or HDBaseT receiver or directly to an HDBaseT enabled display device. It can also be integrated into an XTP CrossPoint matrix switcher system.
Audio Integration Capabilities and Available Power Amplifiers The DTP2 CrossPoint 82 can also serve as the central component for audio system integration. It includes eight- input audio switching, two mic/line inputs with phantom power, HDMI audio embedding and de-embedding, and Extron ProDSP with mixing, ducking, tone adjustments, and more.
Page 12
Supports DisplayPort Single Stream Transport (SST) data rates up to 21.6 Gbps. • Supported HDMI 2.0 specification features include data rates up to 18 Gbps, Deep Color, and HD lossless audio formats. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Introduction...
Page 13
Extron XTP DTP 24 shielded twisted pair cable is strongly recommended for optimal performance. • Compatible with CATx shielded twisted pair cable — The DTP2 CrossPoint 82 supports a maximum transmission distance of 330 feet (100 meters) for all compatible resolutions when used with CATx shielded twisted pair cable.
Page 14
• Internal video test patterns and pink noise generator for calibration and setup — The DTP2 CrossPoint 82 provides several video test patterns and audio pink noise to facilitate proper system setup and calibration of display devices. • HDMI to DVI Interface Format Correction — Automatically enables or disables embedded audio and InfoFrames, and sets the correct color space for proper connection to HDMI and DVI displays.
Page 15
HDMI sources. • Output standby mode — The DTP2 CrossPoint 82 can be set to automatically mute video and sync output to the display device when no active input signal is detected. This allows the projector or flat panel display to automatically enter into standby mode to save energy and enhance lamp or panel life.
Setup and Configuration Methods Control the DTP2 CrossPoint 82 switchers using one or more of the following methods: • The front panel controls and the on-screen display (OSD) menu (see Using the On-Screen Menu System on page 22). • A computer, a touch screen panel, or any other device that sends and receives serial communications through the USB, RS-232, or Ethernet port.
Page 17
FLAT PANEL 4K Display AUDIO IN HDMI IN HDMI Laptop Extron Local 4K Monitor DTP T HWP 4K 231 D Transmitter Figure 2. DTP2 CrossPoint 82 IPCP MA 70 Application Example DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Introduction...
Installation This section contains information on how to connect cables to the DTP2 CrossPoint 82 models. Topics in this section include: • Installation Overview • Rear Panel Connections • Connection Details • Twisted Pair Recommendations for DTP, XTP, and HDBT Communication Installation Overview 1.
Page 19
66), the on-screen display (see Input Submenu on page 29), or PCS (see the Twisted Pair DTP2 CrossPoint 82 Help File). For cable wiring and recommendations, see Recommendations for DTP, XTP, and HDBT Communication on page 18. ATTENTION: •...
Page 20
Consumer Electronics Control (CEC) — CEC control commands control basic control functions such as power on and off, input switching, volume, and mute. The DTP2 CrossPoint 82 can issue CEC commands to a display device through the HDMI and DTP2 ports.
Page 21
Figure 7. RS-232 Wiring Reset LED — This green LED remains lit while the DTP2 CrossPoint 82 has power. While the Reset button (see , below) is being pressed and held, this LED blinks every 3 seconds to indicate the level of reset...
Page 22
(see on page 16). IPCP Pro 355M Control Processor (DTP2 CrossPoint 82 IPCP SA and DTP2 CrossPoint 82 IPCP MA 70 only) — The DTP2 CrossPoint 82 IPCP models include a built-in IPCP Pro 355M Control Processor (see figures 4 and 5).
Page 23
LAN and AV LAN connections (ports) are connected to separate networks, the LAN and AV LAN IP address schemes must be on different subnetworks. LA N port — Single Ethernet connector. The DTP2 CrossPoint 82 base model has a LAN connector to the left of the Remote RS-232 connector (see...
Wire the audio input and output connectors as shown in figure 9. Use the supplied tie wrap to strap the audio cable to the extended tail of the connector. NOTE: These instructions do not apply to the amplified audio output connector on the DTP2 CrossPoint 82 IPCP SA and MA models.
Stacked Figure 10. LockIt Bracket Mounting Orientations The DTP2 CrossPoint 82 HDMI connectors require the LockIt brackets to be mounted as follows: • HDMI inputs 2, 4, and 6 — Side mounted. Can be stacked with the connectors below them.
DTP transmitters or receivers. • N’utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d’Extron ou le câble STP201 pour relier le appareil avec les émetteurs ou les récepteurs DTP. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation...
Page 27
Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles. • Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners. • Separate twisted pair cables from AC power cables. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Installation...
Navigation buttons Logo button Mic and Volume knobs and LED indicators Output selection buttons IPCP Pro LED indicators Status LED indicators Figure 15. Front Panel — DTP2 CrossPoint 82 IPCP MA 70 DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
Page 29
Mic and Volume knobs and LED indicators — Rotate the Mic knob to adjust the microphone level. Rotate the Volume knob to adjust the program or output volume level (configurable, see the DTP2 CrossPoint 82 PCS Help File for more information). The eight LED indicators for each knob light according to the level being adjusted.
The on-screen menu has a default timeout of 60 seconds. • The screen examples shown in this section show the OSD screens of a DTP2 CrossPoint 82 IPCP SA. The OSD for your product may differ slightly. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
Figure 17. On-screen Menu Example The on-screen menu contains eight submenus with various submenu items of adjustable settings or device information (see the Submenu Items table on the next page. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
NOTE: To cancel a change, press the button to return to the submenu list (left column) without > < pressing Enter. Then, press the button to move to a different submenu. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
The read-only Device Info screen is listed first in the submenus (left) panel. This screen contains information about your DTP2 CrossPoint 82, including unit name, firmware version, internal temperature in Celsius and Fahrenheit, and format and signal information for the selected input device, all outputs, and the loop out.
> IP Address — Press the and buttons to switch between octets. Press the buttons to change < the value of a selected octet. The default address is 192.168.254.254. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
To adjust the vertical size, press the as indicated by the blue up and down arrows after the V setting. 2. When finished, press Enter to return to the OSD menu. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
Page 36
> buttons to adjust the image sharpness. The range is 0 through 127. The default < is 64). Press Enter or to select the changes and return to the submenu. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
HDCP Authorized — This feature determines if a digital input reports as an HDCP authorized sink to a source. Select this item to enable or disable HDCP communication by selecting whether the DTP2 CrossPoint 82 input reports to the source as an authorized HDCP sink. Press Enter to select this item, ...
Page 38
Capture EDID — Select this item to capture the EDID of the sink device attached to an output and save it to one of the 10 custom EDID slots. The DTP2 CrossPoint 82 assigns the captured EDID to its selected input. To capture an EDID: 1.
Page 39
**Rates supported only with 4:2:0 color sampling on an input in DTP or XTP mode. 4:4:4 sampling supported from DTP2 transmitters or on DisplayPort or HDMI inputs only. ***4096x2160 rates are available only for output resolution and cannot be selected for input EDID. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
HDCP notification, and Loop Out format and connected input. • Output Rate — Select this item to specify the output resolution and refresh rate. The DTP2 CrossPoint 82 switchers have a range of resolutions from which to choose (see the...
Page 41
Auto (based on the EDID of the sink) (default) • DVI RGB 444 • HDMI RGB 444 Full • HDMI RGB 444 Ltd • HDMI YUV 444 Ltd • HDMI YUV 422 Ltd DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
Page 42
• User Image — Displays a user-uploaded image. To upload images, use the PCS software Logo screen (see the DTP2 CrossPoint 82 Help File for instructions). • Loop Out — Lets you select the input for the unscaled, looped output. Press Enter to select this item, then ...
For the twisted pair inputs in DTP mode, the analog audio is taken from the analog audio connector on the DTP Transmitter. • For the TP inputs in XTP mode, the analog and Auto formats are not available. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
Page 44
Use PCS to configure DSP and other audio parameters for the audio inputs and outputs (see the DTP2 CrossPoint 82 PCS Help File for detailed instructions). • Use SIS commands to configure non-DSP audio parameters (see the commands for Audio Configuration commands starting on page 61). DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
By default all test patterns include a single pixel wide crop pattern line. • The Audio Test pattern displays a crop pattern and also outputs pink noise at 48 kHz, 24 bit. • Test pattern selections persist through a power cycle. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
Page 46
Horizontal Shift (Logo) Vertical Shift (Logo) commands on page 72) or PCS (see the DTP2 CrossPoint 82 PCS Help File). 3. Press Enter to confirm your selection. NOTE: The switcher exits screen saver mode when the front panel Menu or Enter button is pressed, a video test pattern is activated, or an active input is detected.
Page 47
(approximately 5 seconds). The message remains for approximately 1 minute after the reset is complete to allow time for the display device to sync with the DTP2 CrossPoint 82 output. NOTE: The equivalent SIS command is E ZXXX } . This command does not affect the current password or the initial factory-set serial number.
• Gateway — Press the buttons to select an octet of the gateway address. Press the buttons < to adjust the value of the selected octet. The default is 0.0.0.0. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
A matrix switcher with multiple types of video inputs (such as an XTP matrix switcher) can be placed upstream from the DTP2 CrossPoint 82 to expand the number of video sources.
Power Save Modes Power The DTP2 CrossPoint 82 can be placed into a standby (low power) mode via SIS commands (see the Save commands on page 70) in order to conserve power. To restore the unit to full power mode, enter the appropriate SIS command, press any front panel button, switch inputs via SIS command, or cycle power to the unit.
RS-232 communication can be sent to the far end of the twisted pair connection via a LAN or an AV LAN (IPCP models only) connector. A control signal applied to a DTP2 CrossPoint 82 LAN port can be routed to the RS-232...
Ethernet to RS-232 insertion, in which an Extron controller provides control of an HD camera via the DTP2 CrossPoint 82 and a DTP HDMI 4K 230 transmitter. Configure this type of insertion as follows: 1.
Page 53
By default the UART start point is 2000. You can change the starting port number by any of the following methods: • Using the Product Configuration Software (see DTP2 CrossPoint 82 PCS Help file) • Using SIS commands (see the command to...
1. Connect the COM (serial) port of the control system to the Over TP IR captive screw port (output port 2 in this example). 2. Connect the TP cable from the DTP2 CrossPoint 82 RJ-45 Out connector to the DTP input of the endpoint. 3. Connect the endpoint to the device to be controlled.
• For initial setup: On the rear panel of the DTP2 CrossPoint 82, a label is attached containing the following: The factory-configured passwords for all accounts on this device have been set to the device serial number. Passwords are case-sensitive.
E25 — Device not present E13 — Invalid value E28 — Bad filename or File not found E14 — Not valid for this configuration E33 — Bad file type for logo DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation...
If the unit does not support or recognize an entered command, it ignores the command and nothing happens. table on the next page shows the resolutions and refresh rates of the available EDIDs for the DTP2 CrossPoint 82 Series. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 58
***4096x2160 rates are available only for output resolution and cannot be selected for input EDID. ****4:4:4 color sampling at these scaled output rates is available only to a DTP2 Rx. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Tie and untie commands do not apply to the loop output. Use the LOUT command to set loop output ties. = Input name (text label) Can contain up to 32 characters, excluding: , (comma) ,*, and Default = Video • Input• DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 60
0 = No input signal detected, 1 = DVI, 2 = HDMI, 3 = DisplayPort = Input digital video format (view only) Input EDID and Output Resolutions EDID table on page 50. = EDID emulation DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 61
1 = Fill — Each input rate fills the entire output raster (default). = Aspect ratio setting 2 = Follow — Each input rate is displayed with its native aspect ratio. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 62
Horizontal size: 10 to 8192 Vertical size: 10 to 4800 Four digit response with zero padding and preceded by + or –. The logo vertical position allows up to ±2400. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 63
2 = DTP2/XTP/HDBT output 2 3 = HDMI/DVI Loop output 0 = Unmute video = Output video mute 1 = Mute video to black screen 2 = Mute video and sync DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 64
7 = HDMI YUV 422 Limited — YUV 422, 16-235 If the switcher is in DVI mode and a rate greater than 165 MHz is selected, the HDMI output defaults to HDMI RGB 444 Full. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 65
0 = Active input detected, timer not running = Screen saver status 1 = No active input, timer running, output sync still active 2 = No active input, timer expired, output sync disabled DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 66
1 through 16. The response is three digits padded with leading zeros. = User logo number 101 = No signal, screen saver user logo or image is displayed. = User HDCP logo displayed DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 67
= Blue of RGB key (available only when = Level key (available only when = Key effect setting through = Key effect = Disable, = Transparency, = RGB key, = Level key, = Alpha key DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 68
= Preset name (text label) Up to 32 characters, excluding: (comma) , , and 1 through 16. Response is three digits, padded with zeros. = Input preset number DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 69
On the DTP2 CrossPoint 82, when Input 7 or 8 is set to DTP mode, the switcher uses analog audio from the remote DTP transmitter instead of analog audio from the rear panel of the DTP2 CrossPoint 82.
Page 70
= Playback slot number 1 through 16 Highest priority for playback is slot 1, descending to lowest priority 16. 0 = No repeat, 1 = Repeat = Repeat play DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 71
Number of seconds to wait before repeating playback on the current audio file, if repeat = Playback delay has been enabled. 1 through (1-300 seconds delay between repeats). 0 = No delay DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 72
1 = Seamless cut (default) — The last frame of video freezes on the screen, then cuts to the newly selected input. 0 = Video, TMDS, or DP signal not detected Video signal status 1 = Video, TMDS, or DP signal detected DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 73
HDCP user logo is visible only if a single HDCP non-compliant display is attached, or if both attached displays are non-HDCP compliant. If the DTP2 CrossPoint 82 is connected to one compliant and one non-compliant display at the same time, only a green or black screen with no text or logo appears on the non-compliant display.
Page 74
Absolute system reset, Same as absolute system reset retain IP settings E ZQQQ } ) except that IP address, subnet mask, gateway address, DHCP, and port mapping are not reset. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 75
0 = IP configuration (ip.cfg) = Configuration type 2 = Unit-specific parameters (box.cfg) NOTE: Configuration files are stored in the directory /nortxe-backup, created on the unit by the Save command. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 76
DTP2 CrossPoint 82 IPCP MA 70 — 60-1615-03 X3& = Model description Digital•Presentation•Matrix Digital•Presentation•Matrix,•IPCP•PRO•355M,•and•Stereo•Amplifier Digital•Presentation•Matrix,•IPCP•PRO•355M,•and•Mono•Amplifier 0 = Unmuted = Video output mute 1 = Muted to black screen 2 = Muted video and sync DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 77
Example: The DTP2 CrossPoint 82 can send out a notice of a change in some setting without receiving a query via a PC or a control system. That change could have been a result of an internal process or a selection made via the PCS program.
Page 78
00-05-A6 Prefix representing subnet mask bits (subnet mask value in CISG = Subnet mask in CISG commands commands). Default = /24, which represents the default subnet mask, 255.255.255.0. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 79
View the echo setting for the current ECHO SIS via SSH connection. Verbose modes 2 and 3: X1)] Echo KEY: 0 = Off or disabled, 1 = On or enabled = Echo status DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 80
• If the admin password is cleared, the user password is cleared also. NOTE: A user password cannot be assigned if no administrative password exists. An E14 error code is returned. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
60002 Line Output 3 60008 DTP2/XTP/HDBT R 60003 Line Output 4 60009 DTP Analog L 60004 Amp L or Mono 60010 DTP Analog R Amp R 60005 60011 DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 82
1 Mic Volume 3 Program Volume 5 Line Volume 7 Bass 9 Output Volume 2 Mic Mute 4 Program Mute 6 Line Mute 8 Treble 10 Output Mute DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply by 10. For = Increment or decrement value mute values, use 0 or 1 as the value. X10& 0 = unmuted, 1 = muted = Group master mute status DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Levels use a 10x multiplier system with no decimal places. For example, a level of +10.4 dB would be entered as and a level of -3.2 dB would be entered as X11! Mute or Phantom power status Disabled, = Enabled DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
+10.4 dB would be entered as 104 and a level of -3.2 dB would be entered as -32. X11! = Mute or Phantom power status Disabled, 1 = Enabled DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
= CEC data — User selected elements (0 through 15) in the form of a percent sign followed by two hex digits. Example: %2A%07%FF X21) CEC address byte — In the form of % sign followed by two hex digits. Example: %E0 = Extron output (14 to TV DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Example: %2A%07%FF X21) = CEC address byte In the form of a percent sign followed by two hexadecimal digits Example: %E0 = Extron output (14) to TV (0) DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
Page 88
Example: %2A%07%FF X21) = CEC address byte In the form of a percent sign followed by two hexadecimal digits Example: %E0 = Extron output (14) to TV (0) DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • SIS Configuration and Control...
CrossPoint 82 via a USB or TCP/IP connection. The graphical interface includes the same functions as those on the device front panel with additional features that are available only through the software. This section describes the software installation and communication (see the DTP2 CrossPoint 82 PCS Help file for detailed control information). Topics in this section include: •...
The Device Discovery panel displays accessible Extron devices connected directly to the PC or to a LAN or WAN. Devices are identified and sorted by model, IP address, device name, or connection method. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
Page 91
Click the Apply and Connect button to accept the changes and connect to the selected device. A new device configuration tab opens. • Click the Cancel button to cancel any pending changes and return to the Device Discovery panel. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
To connect indirectly to a device through a control processor via an AV LAN: If your DTP2 CrossPoint 82 is connected to an AV LAN, you can connect to it through a control processor such as an Extron IPCP, as follows: 1.
2. Select the desired device model from the Device Models list (see figure 39, ). In figure 39, DTP2 CrossPoint 82 IPCP SA was selected. 3. Click the Configure button ( ). A new offline device configuration tab opens. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
Software Overview NOTE: For details about specific software features, see the DTP2 CrossPoint 82 PCS Help File. Figure 40. PCS Main Window Each device screen has a Device drop-down menu for configuration options. The Software menu contains software configuration and information options.
Page 95
) view the software build number and more information. To display details about third-party software packages and associated licensing, click Licenses ( 3. Click the OK button ( ) to close the dialog box. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Configuration Software...
) to leave the software open. Device Menu The Device drop-down menu contains options pertaining to device connection, configuration, and information. For details about all these options, see the DTP2 CrossPoint 82 PCS Help File. Figure 46. Device Menu •...
Page 97
• Restore — Opens a submenu containing the following restore options: • Restore this Device — Lets you load a saved configuration for any DTP2 CrossPoint 82 model to the connected device. • Restore to Multiple Devices — Lets you load a saved configuration file for any DTP2 CrossPoint 82 model to multiple devices on the network.
The DTP2 CrossPoint 82 switchers feature an internal web server, displayed as a web page. This page allows you to monitor and adjust certain settings of the DTP2 CrossPoint 82 via a LAN or WAN connection. Use a web browser to view the pages on a PC connected to the switcher LAN port.
Internal Web Page NOTE: Figure 48 shows the web page for a DTP2 CrossPoint 82 IPCP SA model. The pages for the other DTP2 CrossPoint 82 models are identical except for the product name in the Device Info panel, and the Inputs panel.
To view the status and type of all inputs, click the link (named 7 More) in the lower-left corner of the Inputs panel ) on the previous page to view the Inputs dialog box (see figure 50 on page 93 for an example). DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Internal Web Pages...
Figure 50 shows an example of a DTP2 CrossPoint 82 Inputs dialog box. Ties are indicated by a colored bar at the left edge of an input row: green indicates a video tie, red an audio tie, and blue an audio-video tie.
Page 102
1. In the Change Admin Password or Change User Password field, enter a single space. 2. Enter a single space in the appropriate Confirm Password field. 3. Click Save. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Internal Web Pages...
Syncing the DTP2 CrossPoint 82 to the PC To set the DTP2 CrossPoint 82 date and time to match that of your computer: Click Sync to PC at the bottom of the Device Status panel. When the sync is completed, the message shown in figure 52 appears in the upper-right corner of the screen.
2. In the Open dialog box, browse to locate the new firmware file on your computer (by default the file is stored at C:\Program Files (x86)\Extron\Firmware after being downloaded from the Extron web page). NOTE: Firmware files for DTP2 CrossPoint 82 have a .eff extension. Do not attempt to load any other file types.
, on page 91), you can set the IP address, subnet mask, and gateway address for your DTP2 CrossPoint 82, and turn DHCP on and off. You can also view the MAC address of the unit. To set the IP addresses: 1.
Rack Mounting The DTP2 CrossPoint 82 can be rack-mounted using the preinstalled rack ears brackets. UL guidelines for rack mounting The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the DTP2 CrossPoint 82 in a rack. CAUTION: •...
électriques autres que les connexions directes au circuit de dérivation (ex. : les multiprises). Downloading Updated Firmware Figure 58. Downloading Firmware from the Extron Website 1. On the www.extron.com, click the Download tab (see figure 58, DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Reference Information...
Page 109
C:\Program Files(x86)\Extron\ Firmware\DTP2 CrossPoint 82. If there is not already an Extron folder in your Program Files x86 folder, the installation program creates it as well. DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Reference Information...
OK button to close the About - Extron PCS dialog box. • IPCP Pro 355M web page — For DTP2 CrossPoint 82 IPCP models, you can view details about third-party packages and associated licensing used by the IPCP control processor by clicking the License Information button on the internal web pages of the IPCP Pro 355M control processor.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Need help?
Do you have a question about the DTP2 CrossPoint 82 and is the answer not in the manual?
Questions and answers