Twisted Pair Recommendations for DTP Communication

Use the following pin configurations for shielded twisted pair cables.
12345678
TP Wires
Figure 6.

Supported Cables

The switchers are compatible with shielded twisted pair cable (F/UTP, SF/UTP, and
S/FTP).
ATTENTION:

Cable Recommendations

Extron recommends using the following practices to achieve full transmission distances and
reduce transmission errors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the
Pins:
TIA/EIA
T568B
Pin
Wire color
1
White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
Green
6
7
White-brown
8
Brown
TP Connector Wiring
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the device with DTP transmitters or receivers.
N'utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF-4
d'Extron ou le câble STP201 pour relier le appareil avec les émetteurs ou les
récepteurs DTP.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000
XTP DTP 24P/1000 Plenum 1000' (305 m) spool
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard (see figure 6).
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, and couplers. If these pass-through points are required, use
shielded couplers and punch down connectors.
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
Extron DTP T DSW 4K Series • Installation and Operation