Keysight Technologies 8163A/B Programming Manual page 210

Table of Contents

Advertisement

4
Measurement Operations & Settings
:TRIGger
page 217.
response:
none
example:
trig 1
command:
:TRIGger[n][:CHANnel[m]]:INPut
syntax:
:TRIGger[n][:CHANnel[m]]:INPut<wsp><trigger response>
description:
Sets the incoming trigger response and arms the module.
parameters:
IGNore:
SMEasure:
CMEasure:
NEXTstep:
SWStart:
You must prearm a wavelength sweep or a measurement function before an action can be triggered:
First, set the incoming trigger response.
Then:
prearm a wavelength sweep using
page 176. The wavelength of the tunable laser module is set to the start wavelength of the sweep.
or prearm a measurement function using
NOTE: If a trigger signal arrives at the Input Trigger Connector at the same time that the
:SENSe[n][:CHANnel[m]]:FUNCtion:STATe
invalid. You should always discard the first measurement value in this case.
The module performs the appropriate action when it is triggered.
response:
none
example:
trig1:inp ign
affects:
All tunable laser modules except 81950A, power meters, and return loss modules, and attenuators with power control.
If you use the Keysight 816x VXIplug&play Instrument Driver, you can trigger power measurements using HP 8153A Series
power meters.
dual sensors:
Can only be sent to master channel, slave channel is also affected.
210
on page 217 describes the :TRIGger command for advanced users using
Ignore incoming trigger.
Start a single measurement. If a measurement function is active, see
:SENSe[n][:CHANnel[m]]:FUNCtion:STATe
the result is stored in the data array, see
on page 100.
Start a complete measurement. If a measurement function is active,
:SENSe[n][:CHANnel[m]]:FUNCtion:STATe
see
function is performed.
Perform next step of a stepped sweep.
Start a sweep cycle.
[:SOURce[n]][:CHANnel[m]]:WAVelength:SWEep:[STATe]
:SENSe[n][:CHANnel[m]]:FUNCtion:STATe
on page 104, one sample is performed and
:SENSe[n][:CHANnel[m]]:FUNCtion:RESult?
on page 104, a complete measurement
on page 104 command is executed, the first measurement value is
8163A/B, 8164A/B & 8166A/B Mainframes Programming Guide
:TRIGger:CONF:EXTended
on
on page 104.
on

Advertisement

Table of Contents
loading

This manual is also suitable for:

8164a/b8166a/b

Table of Contents