Measurement Operations & Settings
parameters:
The excursion level as a percentage of its maximum value.
Also allowed:
response:
none
example:
sour2:fm:sbsc:lev 80
affects:
Keysight 81960A, 81980A, 81940A, 81989A, 81949A compact tunable lasers.
command:
[:SOURce[n]][:CHANnel[m]]:FM:SBSCtrl:Level[l]?
syntax:
[:SOURce[n]][:CHANnel[m]]:FM:SBSCtrl:LEVel[l]?<wsp>[MIN|MAX|DEF]
description:
Queries the currently set excursion level of the SBS Control frequency modulation.
parameters:
Optional
response:
Returns the currently set excursion level as a percentage of its maximum value.
example:
sour2:fm:sbsc:lev?
affects:
Keysight 81960A, 81980A, 81940A, 81989A, 81949A compact tunable lasers.
132
MIN: minimum programmable value (0%)
MAX: maximum programmable value (100%)
DEF: default preset (*RST) value.
MIN: returns the minimum programmable value (0%)
MAX: returns the maximum programmable value (100%)
DEF: returns the default preset (*RST) value.
->
+8.000E+01<END>