Siemens SIMATIC ET 200pro Series Operating Instructions Manual page 26

Low voltage converter for the distributed i/o system
Hide thumbs Also See for SIMATIC ET 200pro Series:
Table of Contents

Advertisement

Description
3.2 Components for assembling a frequency converter
The minimum configuration of a frequency converter requires the following components:
● a rack,
● a complete interface module including a bus terminating module (in the scope of supply of
the IM),
● the bus module of the frequency converter and the frequency converter itself.
The components described below are examples and represent the minimum configuration of
a standard frequency converter with the safety function STO.
ET 200pro FC-2 with F-RSM
Figure 3-1
Setup the Safe Torque Off (STO) function using local activiation.
Table 3- 1
No.
1
2
26
ET 200pro FC-2 with F-RSM
Components of the ET 200pro FC-2 with F-RSM
Components
Function
Mounting rail
The mounting rail is used to secure all the components of the
ET200pro system easily and allows the components to be connected
to each other efficiently and accurately.
Connection modules
The connection modules are mounted on the interface modules. The
for interface mod-
modules are designed to allow a variety of connections types suitable
ules
for a number of applications.
The follow connection modules are available:
Direct connection:
CM IM DP Direct
ECOFAST:
CM IM DP ECOFAST CU
CM IM DP M12, 7/8"
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
SIMATIC ET 200pro FC-2 converter

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic et 200pro fc-2Simatic et 200pro fc-2 converter

Table of Contents