Inverter
● What data does my inverter have?
● How is my inverter set?
● What technological requirements must the drive fulfill?
Data for a standard induction motor
Before starting commissioning, you must know the following data:
● Which motor is connected to the inverter?
Note down the Article No. of the motor and the motor's nameplate data.
If available, note down the motor code on the motor's nameplate.
Figure 6-1
● In which region of the world is the motor to be used?
- Europe IEC: 50 Hz [kW]
- North America NEMA: 60 Hz [hp] or 60 Hz [kW]
● How is the motor connected?
Pay attention to the connection of the motor (star connection [Y] or delta connection [Δ]).
Note the appropriate motor data for connecting.
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
Description (Page 23)
Factory setting of the inverter control (Page 74)
Selecting the control mode (Page 75)
Minimum and maximum speed (Page 76)
Example of the rating plate for a standard induction motor
Commissioning
6.3 Preparing for commissioning