4. The "Without copy protection" option is active by default. If an appropriate memory card is
inserted in the Control Unit, you can select one of two copy protection options:
– With basic copy protection (permanently linked to the memory card)
– With extended copy protection (permanently linked to the memory card and Control
Select the required copy protection option.
5. If, in spite of active know-how protection, you wish to permit diagnostic functions, activate
option "Allow diagnostic functions (trace and measuring functions)".
6. Click on "Define"
7. Enter your password. Length of the password: 1 ... 30 characters.
Recommendation for assigning a password:
– Only use characters from the ASCII set of characters.
– For an adequately secure password, the password must have a minimum length of 8
8. The "Copy RAM to ROM" option is active as standard.
The option must be active in order that the inverter keeps the know-how protection
settings after switching off and switching on the power supply.
9. Click on "OK".
You have activated know-how protection.
Preventing data reconstruction from the memory card
As soon as know-how protection has been activated, the inverter only backs up encrypted
data to the memory card.
In order to guarantee know-how protection, after activating know-how protection, we
recommend that you insert a new, empty memory card. For memory cards that have already
been written to, previously backed up data that was not encrypted can be reconstructed.
Changing the password
Procedure with STARTER
Select the inverter in the project and open the dialog screen form using the shortcut menu
"Know-how protection drive unit → Change password ...".
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
Unit)
If you use arbitrary characters for the password, changing the windows language
settings after activating know-how protection can result in problems when
subsequently checking a password.
characters, and must include uppercase and lowercase letters as well as a
combination of letters, numbers and special characters.