ET 200pro FC-2 with F-Switch
Figure 3-2
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
Components
Function
PROFIBUS DP
The interface module interconnects the ET 200pro with the DP master
interface module
and prepares the data for the electronic modules.The unit is delivered
with bus module
with the terminating module. The interface module is already mounted
on the bus module.The bus module is the mechanical and electrical
connection element between the various ET 200pro modules.The
terminating module terminates the ET 200pro.The following interface
modules are available for PROFIBUS DP:
Safety Local repair
The F-RSM is used to trigger the safety functions of the converter
switch module
through the backplane bus; it switches off the power bus for the motor
(F-RSM) with bus
starters and frequency converters. An F-RSM must always be plugged
module
in the system to the left of the frequency converter and can be con-
trolled only through local safe inputs (Safety Local function).
Converter with bus
The converter is connected to the higher-level controller by way of the
module
bus module and interface module; power and motor are connected
using prefabricated cables.
Terminating module
The ET 200pro bus is terminated with the terminating module
ET 200pro FC-2 with F-Switch
3.2 Components for assembling a frequency converter
IM154-1 DP
IM154-2 DP HF
Description
27