Creating A Project; Transfer Inverters Connected Via Usb Into The Project - Siemens SIMATIC ET 200pro Series Operating Instructions Manual

Low voltage converter for the distributed i/o system
Hide thumbs Also See for SIMATIC ET 200pro Series:
Table of Contents

Advertisement

6.6.2.1

Creating a project

Creating a new project
Procedure
To create a new project, proceed as follows:
1. Start the commissioning software STARTER or Startdrive.
2. In the menu, select "Project" → "New...".
3. Specify a name of your choice for the project.
You have created a new project.
6.6.2.2

Transfer inverters connected via USB into the project

Transferring inverters connected via USB to the project
Procedure
Proceed as follows to transfer an inverter connected via USB to your project:
1. Switch on the inverter power supply.
2. First insert a USB cable into your PC and then into the inverter.
3. The PC operating system installs the USB driver when you are connecting the inverter
and PC together for the first time.
– Windows 7 installs the driver automatically.
– For Windows XP you must acknowledge several system messages.
4. Start the STARTER commissioning software.
5. In STARTER, press the
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
("Accessible nodes") button.
Commissioning
6.6 Basic commissioning
83