2. OPTICS
2.1 EXPOSURE GLASS REMOVAL
1. Open the original feed unit.
2. Remove the two exposure glass holders [A]. (2 hexagon head screws
each.)
3. Remove the exposure glass [B].
NOTE: When reinstalling the exposure glass, make sure that the
beveled edge [C] of the exposure glass must be positioned
upward as shown.
[A]
[B]
5-3
OPTICS
[A]
[C]