31 December 1992
3.5 MANUAL ID CONTROL VS ADS
Manual ID Level
1
2
3
4
5
6
7
8
9
10
11
12
13
3.5.1 Manual ID Control
When in manual image density mode, the user can select one of 26 manual
ID levels. For each level, the intensity of the light output by the exposure
lamp (as measured by the light sensor) is fixed. This is shown in the above
table. For manual ID levels 2 through 12, the development roller bias also
varies. (See the section on development bias.)
Light Sensor
Output [V]
0.74
0.80
0.81
0.82
0.84
0.86
0.90
0.94
0.99
1.05
1.10
1.15
1.18
2-11
Manual ID Level
14
15
16
17
18
19
20
21
22
23
24
25
26
EXPOSURE
Light Sensor
Output [V]
1.21
1.25
1.29
1.33
1.37
1.41
1.45
1.50
1.54
1.59
1.64
1.69
1.74