Exposure Glass Removal - Ricoh FT8680 Service Manual

Table of Contents

Advertisement

OPTICS
2. OPTICS

2.1 EXPOSURE GLASS REMOVAL

[C]
1. Lift the document feeder.
2. Remove the front scale holder [A] (2 screws and 2 plates).
3. Remove the front scale [B] (2 screws).
3. Loosen the three screws [C] securing the rear scale.
4. Remove the exposure glass [D].
NOTE: When reinstalling the exposure glass, make sure the mark on the
glass edge [E] is facing up.
[D]
5-4
31 July 1995
[E]
[B]
[A]
A171R572.img