DEVELOPMENT
5.5 TONER DENSITY SENSOR REPLACEMENT
1. Open the middle unit.
2. Open the toner cartridge cover and take out the toner cartridge.
3. Remove the development filter. (See Development Filter Removal.)
4. Remove the original exit guide [A] (2 screws).
5. Remove the middle right cover.
6. Remove a screw [B] and push down the harness bracket [C].
7. Remove the toner cartridge holder [D] (Right......2 screws,
8. Remove the toner density sensor holder [E] (2 screws and 1 connector).
9. Remove the toner density sensor [F] from the holder.
NOTE: After replacing the toner density sensor, replace the developer,
perform Initial Conditioning (SP#5) and Toner Density Sensor
Voltage Adjustment (SP#35).
[A]
[E]
[D]
Left.........loosen 1 screw).
5-28