FUSING
9.4

FUSING THERMOFUSE REPLACEMENT

[B]
1. Remove the fusing unit. (See Fusing Unit Removal.)
2. Remove the fusing upper cover (4 screws).
3. Take the thermofuse harness [A] out from the clamps [B] (7 clamps, 1
screw each).
4. Remove the thermofuse holder [C] (1 screw).
5. Remove the thermofuse terminal [D] (2 screws).
6. Remove the both end connectors [E] of the thermofuse harness.
7. Replace the thermofuse and the harness.
[A]
[E]
5-54
[C]
[E]
[B]
31 December 1992
[D]