31 December 1992
[A]
[D]
5. Remove the left [A] and right [B] gird holders.
6. Remove the 4 grid wires [C] (4 springs).
7. Remove the grid wire terminal [D] (1 screw).
8. Remove the left [E] and right [F] endblock covers.
9. Remove the wire cleaner [G] (1 screw).
10. Replace the corona wire [H].
NOTE: 1) Handle the new corona wire by the ends only. Oil from your
hands may cause uneven charge on the drum.
2) Do not expand the corona wire.
3) Do not rub the corona wire with rough material (sand paper,
etc.) as this will damage the corona wire.
4) Do not use any solvents to clean the wire as this will cause
uneven charge on the drum.
5) Do not miss the two corona wire cushions [I].
[C]
[E]
[H]
[I]