Page 76 of 212
Performing the upgrade
Table 11
QPC441 (QPC440) 3PE Card installed in the CP PIV Core/Net modules
Jumper Settings: For F/FE5 vintage set Jumper RN27 to "A"; for GE5 vintage set Jumper J5 to
short pins 1(dot) & 2.
Switch Settings
Module
CP PIV Core/Net modules only
Core/Net 0 (Shelf 0)
Core/Net 1 (Shelf 1)
NN43021-461
Standard 06.03
Procedure 16
Relocating Network cards to CP PIV Core/Net 0
1
Move any existing cards from slots 0-11 of the old Core/Net 0 card cage
to the same slots (0-11) in the new NT4N40 Core/Net 0 card cage.
2
Connect the tagged cables to the relocated cards.
3
When you move the 3PE card, check the switch settings and jumpers.
Table 11, "QPC441 (QPC440) 3PE Card installed in the CP PIV
See
Core/Net modules," on page 76
a.
All 3PE cards must be vintage F or later.
b.
Check that the RN27 Jumper is set to "A" (F/FE5 vintage) or J5
jumper shorts pins 1(dot) & 2 (GE5 vintage).
4
The settings for 3PE cards in Core/Net shelves are different from those in
all other shelves.
the CP PIV Core/Net modules," on page 76
cards installed in CP Core/Net Modules.
Group 0
Group 0
Procedure 17
Moving Clock Controller 1
1
Remove Clock Controller 1 from the Core module.
2
Set the Clock Controller 1 switch settings according to Table 12, "Clock
Controller switch settings for NTRB53," on page 78 and Table 13, "Clock
Controller switch settings for QPC471H, QPC771H," on page 79.
June 2014
.
Table 11, "QPC441 (QPC440) 3PE Card installed in
End of Procedure
D20 switch position
1
2
3
off
on
on
off
on
on
shows the 3PE settings for
4
5
6
off
on
on
off
on
on
7
8
on
on
on
off