Preparing and planning for the upgrade
2
Load the Customer Configuration Backup and Restore (LD 143). At the
prompt, enter:
LD 143
3
Run the ABKO backup (LD 143).
ABKO
Result: If the backup is successful, the system displays a message that
states that the database backup is complete and generates a report that
indicates which floppy drives were used.
4
If there are validation errors, repeat the procedure.
CAUTION — Service Interruption
Loss of Data
If the backup is not successful, do not continue; contact
your technical support organization. Any backup
problems must be corrected before the system is
upgraded to CP PIV.
5
Once the backup is complete, type:
****
If the system is equipped with IOP/CMDU cards the
database must be converted with the Database Transfer
utility below.
If the system is equipped with IODUC cards, the
database should be data dumped (EDD) to a blank 2
MByte floppy.
All systems can be converted by
conversion lab.
Load program
Run backup
Exit program
IMPORTANT!
61C to CS 1000M SG CP PIV Upgrade
Page 41 of 212
Avaya
in the software