Switching call processing

NN43021-461
Standard 06.03
Performing the upgrade
Procedure 44
Switching call processing
1
Enter LD 135 on Core/Net 1 and issue the SCPU command. Call
processing switches to Call Server 0 and service is interrupted.
LD 135
SCPU
****
Core/Net 0 is now the active call processor.
Procedure 45

Testing Core/Net 0

From Core/Net 0, perform these tests:
1
Perform a redundancy sanity test:
LD 135
STAT CPU
TEST CPU
2
Check the LCD states:
a.
Perform a visual check of the LCDs.
b.
Test LCDs:
LD 135
TEST LCDs
DSPL ALL
June 2014
Switch CPUs
Exit program
Load program
Obtain status of CPU and memory
Test CPU
Load program
Test LCDs