Performing the upgrade

Check equipment received

Check vintage requirements for existing hardware

NN43021-461
Standard 06.03
— One blank CF card for database backup
One CS 1000 Release 7.5 Documentation CD
This section describes the minimum equipment required for CP PIV.
Additional equipment can also be installed during the upgrade. Verify that all
equipment has been received.
Meridian 1 Option 61C CP PIV equipment is configured at the factory
according to customer requirements. Some cards and power supplies are
shipped in separate packages to prevent damage to cards.
Before the upgrade, check that equipment on the order form is also on the
packing slip. Check that all equipment has been received. If any items are
missing, contact your supplier for replacements before you begin the upgrade.
WARNING
Service Interruption
DO NOT proceed with the upgrade if any of the required
equipment is missing. All equipment must be received to
complete the upgrade.
Make sure that existing hardware meets the following minimum vintage
requirements for CP PIV:
The NT4N65 cCNI card must be minimum vintage of AC
The NT4N48 System Utility card must be minimum vintage AA
The QPC441 3-Port Extender (3PE) cards must be minimum vintage F.
The NTRB53 Clock Controller cards must be minimum vintage AA.
The existing QPC471 Clock Controller cards must be minimum vintage
H or the QPC775 Clock Controller cards (all countries except USA) must
be minimum vintage E.
NT6D41CA (DC) Power Supply