Converting The 4 Mbyte Database Media To 2 Mbyte Database Media - Avaya 1000M Upgrade

Cs 1000m sg cp piv
Table of Contents

Advertisement

Page 42 of 212
Preparing and planning for the upgrade
NN43021-461
Standard 06.03
Procedure 5

Converting the 4 MByte database media to 2 MByte database media

Before the system is upgraded to CP PIV, the database must reside on a
2 MByte floppy disk for conversion to CF. Systems with an IODU/C drive
already have 2 MByte floppy drive and can skip this procedure.
If the database is on a 4 MByte floppy (the system has an IOP/CMDU), the 4
MByte customer database must be transferred to a 2 MByte floppy disk.
1
Split the Cores and transfer call processing to Core 0.
2
Install the Database Transfer Utility diskette into the floppy drive on the
IOP/CMDU in Core 1.
3
Press the reset button (MAN RST) on the Call Processor card in Core 1
to reboot the system. Start the Database Transfer Utility Tool.
CAUTION — Service Interruption
Select only options:
• <t> Tools Menu from the Install menu, and
• <s> To archive database from the Tools menu.
DO NOT select any other options. Other options can
result in operating system corruption.
4
From the installation menu select:
<t>
<s>
<cr> <a>
<cr> <a>
5
The message displays "Database backup complete!" and the Tool menu
appears again after the backup completes correctly.
June 2014
Go to the Tools menu.
Archive existing database.
Continue with archive (insert blank 2 MByte
diskette from the software kit into the floppy drive
in Core 1).
Diskette is now in floppy drive in Core 1.