Power Down Core/Net 1 - Avaya 1000M Upgrade

Cs 1000m sg cp piv
Table of Contents

Advertisement

3
Remove the system monitor from the rear of the pedestal on Core 0.

Power down Core/Net 1

For AC-powered systems: set the MPDU circuit breaker located at the left end
of the module to OFF (down position).
For DC-powered systems: set the breaker for the Core 1 module in the back
of the column pedestal to OFF (down position).
Procedure 14
Removing Core 1 cables and card cage
1
Label and disconnect the Clock Controller 1.
a.
Disconnect the NT8D76AC cable from the Clock Controller 1
faceplate card.
b.
If primary and secondary clock reference cables are connected to the
Clock Controller 1 faceplate, disconnect them last.
2
Label and disconnect all cables from the front of the module.
3
Tape over the contacts to avoid grounding.
4
Tie all cables to the sides so the working area in front of the card cage is
totally clear.
Performing the upgrade
End of Procedure
CAUTION — Service Interruption
Service Interruption
Call processing is interrupted for approximately 60
minutes while the procedures are completed.
DANGER OF ELECTRIC SHOCK
In a DC-powered system, power to the column can
remain on during the following procedures. In an
AC-powered system, however, power to the entire
column must be shut down throughout the procedures.
61C to CS 1000M SG CP PIV Upgrade
Page 67 of 212

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1 61c

Table of Contents