Connecting a Signaling Server

NN43021-461
Standard 06.03
lnstalling a Signaling Server
This section contains instructions for connecting a Server to the ELAN and
TLAN subnet of a CS 1000M system. It also contains instructions for
connecting a maintenance terminal to the Server.
A Server card is inserted into a slot of a Universal Equipment Module (UEM).
UEMs do not have built-in ELAN and TLAN Ethernet ports. You must install
Ethernet ports on the back of the UEM to enable the Server to connect to the
ELAN and TLAN subnets of your Communication Server 1000 system (see
Procedure 47: "Installing ELAN and TLAN Ethernet ports on the back of a
Communication Server 1000M UEM" on
Perform Procedure 48 to connect a Server card to the ELAN and TLAN
subnets of a Communication Server 1000M system.
Connecting a Signaling Server to the ELAN and TLAN subnets of a CS
1000M system causes a service disruption.
Procedure 48
Connecting a Server Card to the ELAN and TLAN subnets of a
Communication Server 1000M system
1
Insert the end of an RJ-45 CAT5 Ethernet cable (not supplied) into the
ELAN network interface port (ELAN port) on the back of the
Communication Server 1000M UEM. (You installed this ELAN port at the
back of the UEM when you installed the Signaling Server in the UEM. For
more information, see Procedure 47: "Installing ELAN and TLAN Ethernet
ports on the back of a Communication Server 1000M UEM" on
2
Insert the other end of the RJ-45 CAT5 Ethernet cable into an Ethernet
port on the ELAN Ethernet switch.
3
Insert the end of another RJ-45 CAT5 Ethernet cable (not supplied) into
the TLAN network interface port (TLAN port) on the back of the
Communication Server 1000M UEM. (You installed this TLAN port at the
back of the UEM when you installed the Signaling Server in the UEM. For
more information, see Procedure 47: "Installing ELAN and TLAN Ethernet
ports on the back of a Communication Server 1000M UEM" on
June 2014
page
164.)
IMPORTANT!
page
164.