Moving Clock Controller 0 - Avaya 1000M Upgrade

Cs 1000m sg cp piv
Table of Contents

Advertisement

Table 16
QPC441 (QPC440) 3PE Card installed in the CP PIV Core/Net modules
Jumper Settings: For F/FE5 vintage set Jumper RN27 to "A"; for GE5 vintage set Jumper J5 to
short pins 1(dot) & 2.
Switch Settings
Module
CP PIV Core/Net modules only
Core/Net 0 (Shelf 0)
Core/Net 1 (Shelf 1)
Procedure 31
Relocating Network cards to CP PIV Core/Net 0
1
Move any existing cards from slots 0-11 of the old Core/Net 0 card cage
to the same slots (0-11) in the new NT4N40 Core/Net 0 card cage.
2
Connect the tagged cables to the relocated cards.
3
When you move the 3PE card, check the switch settings and jumpers.
Table 16, "QPC441 (QPC440) 3PE Card installed in the CP PIV
See
Core/Net modules," on page 117
a.
All 3PE cards must be vintage F or later.
b.
Check that the RN27 Jumper is set to "A" (F/FE5 vintage) or J5
jumper shorts pins 1(dot) & 2 (GE5 vintage).
4
The settings for 3PE cards in Core/Net shelves are different from those in
all other shelves.
the CP PIV Core/Net modules," on page 117
cards installed in CP Core/Net Modules.
Group 0
Group 0
Procedure 32

Moving Clock Controller 0

1
Remove Clock Controller 0 from the Core module.
2
Set the Clock Controller 0 switch settings according to Table 12, "Clock
Controller switch settings for NTRB53," on page 78 and Table 13, "Clock
Controller switch settings for QPC471H, QPC771H," on page 79.
Performing the upgrade
.
Table 16, "QPC441 (QPC440) 3PE Card installed in
End of Procedure
D20 switch position
1
2
3
off
on
on
off
on
on
61C to CS 1000M SG CP PIV Upgrade
Page 117 of 212
shows the 3PE settings for
4
5
6
off
on
on
off
on
on
7
8
on
on
on
off

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1 61c

Table of Contents