Preparing and planning for the upgrade

Connecting a terminal

NN43021-461
Standard 06.03
Changing the procedure or ignoring the warning boxes could cause longer
service interruptions.
Preserve database backup information for a minimum of
5 days.
Procedure 1
Connecting a terminal
A maintenance terminal is required to access the Core or Core/Net modules
during the upgrade procedure.
1
Connect a terminal to the J25 port on the I/0 panel in the inactive Core or
Core/Net module.
2
The settings for the terminal are:
a.
9600 baud
b.
8 data
c.
parity none
d.
1 stop bit
e.
full duplex
f.
XOFF
3
If only one terminal is used for both Core or Core/Net modules, the
terminal must be connected from side-to-side to access each module.
An "A/B" switch box can also be installed to switch the terminal from side
to side.
June 2014
IMPORTANT!
End of Procedure