Page 314 of 436
Testing Core/Net 1 and Core/Net 0
NN43021-310
Standard 06.01
Powering up the system and initial loading
At this point the system should reload and initialize.
LD 137 modifications
The
commands are not applicable to CP PIV. Instead, the
CMDU/MMDU
following commands are introduced in LD 137.
•
STAT FMD
display text: Status of both Fixed Media Devices (FMD)
command parameter: none
•
STAT FMD 0/1
display text: Status of the specified Fixed Media
Device
command parameter: "core #" with values of 0 or 1
•
STAT RMD
display text: Status of both Removable Media Devices
(RMD)
command parameter: none
•
STAT RMD
display text: Status of the specified Removable Media
Device
command parameter: "core #" with values of 0 or 1
Procedure 49
Testing Core/Net 1
1
Perform a redundancy sanity test:
LD 135
STAT CPU
TEST CPU
2
Check the LCD states:
March 2013
End of Procedure
Load program
Get status of CPU and memory
Test CPU