Cs 1000m sg cp piv
Table of Contents

Advertisement

3
Test the System Utility cards and the cCNI cards:
LD 135
STAT SUTL
TEST SUTL
STAT CNI c s
TEST CNI c s
4
Test system redundancy:
LD 137
TEST RDUN
DATA RDUN
STAT FMD
STAT RMD
5
Install the two system monitors. Test that the system monitors are
working:
LD 37
ENL TTY x
STAT XSM
****
6
Clear the display and minor alarms on both Cores:
LD 135
CDSP
CMAJ
CMIN ALL
Performing the upgrade
Load program
Obtain the status of the System Utility
card
Test the System Utility card
Obtain status of cCNI cards (core, slot)
Test cCNI (core, slot)
Load program
Test redundancy
Test database integrity
Status of Fixed Media Device (FMD)
Status of Removable Media Device (RMD)
Load program
Enable the XMS, where x= system XMS
Check the system monitors
Exit program
Load program
Clear displays on the cores
Clear major alarms
Clear minor alarms